CONNECTING AN ALARM UNIT

CONNECTING AN ALARM UNIT

You can connect a maximum of four alarm units to a recorder.

To connect a CM9760-ALM to a DX9100 recorder using RS-232 communication:

1.Connect a null modem cable from the alarm unitÕs RS-232 port to the recorderÕs RS-232 port.

2.Set the DIP switches on the alarm unit for RS-232 communication. Refer to the CM9760-ALM Installation/Operation manual.

If using RS-422 communication:

1.Connect a cable from the alarm unitÕs RJ-45 COM IN port to the recorderÕs RS-232 port via an RS-232 to RS-422 converter.

2.Set the DIP switches on the alarm unit for RS-422 communication. Refer to the CM9760-ALM Installation/Operation manual.