Pelco CONNECTING A CM9760-CC1, To connect a CM9760-CC1 to a DX9100 recorder, Recorder

Models: DX9100

1 86
Download 86 pages 11.33 Kb
Page 69
Image 69
CONNECTING A CM9760-CC1

CONNECTING A CM9760-CC1

To connect a CM9760-CC1 to a DX9100 recorder:

1.Connect a null modem cable from the CM9760-DTÕs COM A port to the recorderÕs RS-232 port.

2.Connect a null modem cable from the CM9760-DTÕs COM B port to COM 1 or COM 2 port on the CM9760-CC1.

3.Set the jumpers in the data translator for baud rate and parity. Refer to the CM9760-DT Installation/Operation manual.

NOTE: You can also connect the CM9760-DT to one of the CM9760-CC1 SERCOM ports for RS-422 communication.

RECORDER

1

4

 

9

12

 

5

8

 

13

16

Term

75

Term

 

75

Te rm

 

75

Te rm

 

75

Loop

 

HI-Z

Loop

 

HI-Z

Loop

 

HI-Z

Loop

 

 

HI-Z

In

 

 

 

 

 

 

 

 

Out

1

2

3

4

5

6

7

8

In

 

 

 

 

 

 

 

 

Out

9

10

11

12

13

14

15

16

Re l

Alarm Input s

Re l

Alarm Input s

1

1 2 3 4 5 6 7 8 Co m

2

9 10 11 12 13 14 15 16 Com

AUDIO INPUTS

1

5

9

13

2

6

10

14

3

7

11

15

4

8

12

16

NULL MODEM

CABLE

CM9760-DT

COM A

COM B

1 2

12 VAC

 

NULL MODEM

 

RS-232 TO RS-422

CABLE

 

 

CONVERTER

 

 

 

 

CM9760-CC1

 

1

2

PRINTER

COM 1

COM 2

Figure 84. Connecting a CM9760-CC1

NOTE: You do not have to use a CM9760-DT if the CM9760-CC1 has software version 8.0. However, you must set the COM port on the CC1 as an internal data translator. Refer to the CM9760-CC1 Installation/Operation manual.

C636M-E (4/05)

69

Page 69
Image 69
Pelco installation manual CONNECTING A CM9760-CC1, To connect a CM9760-CC1 to a DX9100 recorder, Recorder, CM9760-DT