Pelco ECP290 Example C Validation of 1no. Access Pass, Example D Block Deletion of Access Passes

Models: ECP290 ECP190

1 20
Download 20 pages 29.84 Kb
Page 11
Image 11
Example C: Validation of 1no. Access Pass

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly deleted Holder Number 074. Programming mode beep - every 4 seconds - resumes.

Example C: Validation of 1no. Access Pass

You have just received the additional Access Pass ordered for Alan Jones who had lost his earlier in the week. The last 3no. digits on the Access Pass are 176. Alan Jones is now Holder Number 176 and you have to program the system to accept Holder Number 176.

Enter the Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming Mode.

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly programmed new Holder Number 176. Programming mode beep - every 4 seconds - resumes.

Example D: Block Deletion of Access Passes

You have just been informed that a set of 20 Access Passes reserved for visitors and held in reception have been stolen. You have to immediately delete them to restore system security. The Holder Numbers stolen were 080-099.

Enter the Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming Mode.

After a beep enter on the TELPRO:

A series of 3no. beeps followed by a sharper beep confirms that you have deleted the Holder Numbers. Programming mode beep - every 4 seconds - resumes.

Example E: Changing the Relay/Lock Output Time

You have been asked to change the Relay Output Time to 12 seconds.

Enter the current Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming Mode.

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly reprogrammed the relay output time for 12 seconds. Programming mode beep - every 4 seconds - resumes.

Example F: Changing the Master Code

You have been asked to change the Master Code to 11821.

Enter the current Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming Mode.

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly entered the new Master Code. Programming mode beep - every 4 seconds - resumes.

11

Page 11
Image 11
Pelco ECP290, ECP190 manual Example C Validation of 1no. Access Pass, Example D Block Deletion of Access Passes