Pelco ECP290 manual ECP Door Controller with ACCESS PASS CONTROL, Programming, 000005, 02A0, Step

Models: ECP290 ECP190

1 20
Download 20 pages 29.84 Kb
Page 9
Image 9
ECP Door Controller with

ECP Door Controller with

ACCESS PASS CONTROL

TOP POINTS TO REMEMBER

Programming is effected via the TELPRO programming keypad.

Site Code is always a 5 digit number.

Site Code is always stored in Slot No. 01.

Master Code (Programming Access Code) is always a 5 digit number.

Master Code is always stored in Slot No. 06.

PROGRAMMING

TIP - WHEN YOU ARE PROGRAMMING

It is a good idea to have written down in advance what you want to program. Enter the numbers in quick succession after a beep. Do not wait more than 2-3 seconds in between entering numbers as this will confuse the system.

SET-UP ON INSTALLATION

Wire up according to appropriate electrical wiring schematic for your installation, then power up the Door Controller. Flick the Programming Switch SW1. The unit will start beeping every 4 seconds.

STEP 1

Decide Now -- For how many seconds do you want the door to open:

After a beep enter on the TELPRO:

000005 08

Example

08

seconds

Basic configuration, just do it!

The last 2no. digits, shown as underlined, set the door open time in seconds. You can choose any length between 01 - 99 seconds. For automation control, 01 seconds is usually more than adequate.

A sharp beep confirms that you have correctly entered the above. Programming mode beep - every 4 seconds - resumes.

STEP 2

 

02A0

Basic configuration,

After a beep enter on the TELPRO:

just do it!

A sharp beep confirms that you have correctly entered the above. Programming mode beep - every 4 seconds - resumes.

STEP 3

You must now set the Master Code of your choice. This is the code that allows you to access programming mode without having to open up the Door Controller and flicking switch SW1.

The Master Code is always stored in Slot No. 06.

The Master Code must be a 5 digit number, for example: 19388.

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly entered the Master Code. Programming mode beep - every 4 seconds - resumes.

9

Page 9
Image 9
Pelco ECP290, ECP190 ECP Door Controller with ACCESS PASS CONTROL, Programming, 000005, 02A0, Top Points To Remember, Step