Mode 4 - Dual Security, Access Pass + Keypad Code
00400508 =
È
Relay output time in seconds
User required to present a valid access pass and then enter a valid code or vice versa in order to gain access. A maximum of 27no. 5 digit keypad codes can be set at any one time. Any 1no. of these keypad codes together with a valid access pass is sufficient to gain entry. This feature is also available on the ECP190 Door Controller.
Mode 5 -
00500508 =
È
Relay output time in seconds (this is an example only).
For
Basic operation is as follows:
The presentation of a valid Access Pass on Door 1 activates the relevant lock release relay. If Door 1 is opened, this Access Pass is immediately and automatically barred on Door 1 until it has been presented on Door 2 with Door 2 then being opened. As soon as this Access Pass is presented on Door 2 with Door 2 being opened, it is immediately and automatically barred on Door 2 until it has been presented on Door 1 with Door 1 then being opened etc etc.
Tip Wizard
Access Passes can be programmed into the access control system even if they have not yet been manufactured by Noralsy® . Your customer may have ordered only 50no. Access Passes and would have had delivered, for example holders
It is so easy: B001 B999.
VERY IMPORTANT
Noralsy® Access Passes must not be compared or confused with random Access Passes- for example, certain brands of proximity key - where the onus is on the installation company to “accurately” identify each Access Pass programmed into the system and physically mark them so that they can be “sure” who is issued with what or, those systems, which rely on shadow cards or master keys/fobs for programming purposes.
13