Pelco ECP290, ECP190 manual Very Important, Tip Wizard, It is so easy B001 B999

Models: ECP290 ECP190

1 20
Download 20 pages 29.84 Kb
Page 13
Image 13
Tip Wizard

Mode 4 - Dual Security, Access Pass + Keypad Code

00400508 = Set-Up, Mode 4

È

Relay output time in seconds

User required to present a valid access pass and then enter a valid code or vice versa in order to gain access. A maximum of 27no. 5 digit keypad codes can be set at any one time. Any 1no. of these keypad codes together with a valid access pass is sufficient to gain entry. This feature is also available on the ECP190 Door Controller.

Mode 5 - Anti-Passback

00500508 = Set-Up, Mode 5

È

Relay output time in seconds (this is an example only).

For Anti-Passback to operate, terminals 3 and 4 of J9A1 and J9A2 must be connected to the Door Contacts fitted to the controlled doors. This is imperative because the Door Controller cannot operate Anti-Passback if it does not know whether the door was opened or not.

Basic operation is as follows:

The presentation of a valid Access Pass on Door 1 activates the relevant lock release relay. If Door 1 is opened, this Access Pass is immediately and automatically barred on Door 1 until it has been presented on Door 2 with Door 2 then being opened. As soon as this Access Pass is presented on Door 2 with Door 2 being opened, it is immediately and automatically barred on Door 2 until it has been presented on Door 1 with Door 1 then being opened etc etc.

Tip Wizard

Access Passes can be programmed into the access control system even if they have not yet been manufactured by Noralsy® . Your customer may have ordered only 50no. Access Passes and would have had delivered, for example holders 001-050 on their unique Site Code but, there is nothing to stop you from block programming all 999 holders. It takes the same amount of time to program 1no. Access Pass into the system as it does to program 999 Access Passes! So, future supplies of Access Passes are already programmed into the system and your customer should only ever have to delete lost or stolen Access Passes!

It is so easy: B001 B999.

VERY IMPORTANT

Noralsy® Access Passes must not be compared or confused with random Access Passes- for example, certain brands of proximity key - where the onus is on the installation company to “accurately” identify each Access Pass programmed into the system and physically mark them so that they can be “sure” who is issued with what or, those systems, which rely on shadow cards or master keys/fobs for programming purposes.

13

Page 13
Image 13
Pelco ECP290, ECP190 manual Very Important, Tip Wizard, It is so easy B001 B999