Table B. Data Connector Pin Assignments

 

 

 

 

RS-485

RS-485

 

 

Pin Number

RS-232

RS-422

2-Wire

4-Wire

Manchester

Bi-Phase

 

 

 

 

 

 

 

 

 

1

TX+ (Out+)

T+/R+ (Out+/In+)

TX+ (Out+)

 

 

 

 

 

 

 

 

 

2

TX- (Out-)

T-/R- (Out-/In-)

TX- (Out-)

 

 

 

 

 

 

 

 

 

3

RX+ (In+)

RX+ (In+)

RX+ (In+) (W)

RX+ (In+)

 

 

 

 

 

 

 

 

 

4

RX- (In-)

RX- (In-)

RX- (In-) (B)

RX- (In-)

 

 

 

 

 

 

 

 

 

5

RX (In)

 

 

 

 

 

 

 

 

 

6

TX (Out)

 

 

 

 

 

 

 

 

 

7

TX+ (Out+) (W)

TX+ (Out+)

 

 

 

 

 

 

 

 

 

8

TX- (Out-) (B)

TX- (Out-)

 

 

 

 

 

 

 

 

 

9

Ground

—*

—*

—*

Shield

Shield

 

 

 

 

 

 

 

*Ground may be required based on conditions of installation. Refer to the current version of

 

EIA/TIA-422 and EIA/TIA-485 standards for additional information.

 

 

NOTES:

 

 

 

 

 

 

RX (In), RX+ (In+), RX- (In-), R+ (In+), and R- (In-) denote data input to the transmitter/

 

receiver.

 

 

 

 

 

 

TX (Out), TX+ (Out+), TX- (Out-), T+ (Out+), and T- (Out-) denote data output from the

 

transmitter/receiver.

 

 

 

 

W denotes white wire, and B denotes black wire.

 

 

 

Data ports are not terminated. For RS-422, RS-485 2-wire, RS-485 4-wire, Manchester, and

 

Bi-Phase data signals, termination may be required based on conditions of installation.

 

If termination is required, terminate the data signal at the endpoint of the data bus using a

 

120-ohm resistor.

 

 

 

 

 

 

 

 

 

 

 

 

 

C1645M-A (9/06)