Table C. Troubleshooting with
Indicator Color | Meaning | Possible Cause |
| Corrective Action | |
|
|
|
|
|
|
|
| ) |
| ||
|
|
| |||
|
|
|
|
|
|
Green | A fiber link is | — |
| No action required. | |
| established. |
|
|
|
|
|
|
|
|
|
|
Flashing green | Data activity is | — |
| No action required. | |
| occurring on the fiber |
|
|
|
|
| link; data is being |
|
|
|
|
| transmitted or |
|
|
|
|
| received. |
|
|
|
|
|
|
|
|
| |
Red | Far end fault | Defective fiber transmit port | Replace local module. | ||
| indication (FEFI). | on local module |
|
| |
| The optical signal |
|
|
|
|
| Laser fault on local module | Refer to the Optic Fault LED | |||
| transmitted from this | ||||
| (Optic Fault LED on local | section in this table. | |||
| port is not detected | ||||
| module flashes red). |
|
| ||
| by the remote link |
|
| ||
|
|
|
|
| |
| Defective fiber receive port | Replace remote module. | |||
| partner. | ||||
| on remote module |
|
| ||
|
|
|
| ||
|
|
|
|
| |
| NOTE: The Optic Fault LED on the remote module is red. Refer to the Optic Fault | ||||
| LED section in this table for additional information. |
| |||
|
|
|
|
|
|
|
|
|
|
| (Continued on next page) |
28 | C2607M (2/07) |