Pelco IS210 Dw/Cw Series Wide Dynamic Range Adjustments, SW1-1 Video Format, SW1-2 Line Sync

Models: IS210

1 24
Download 24 pages 27.77 Kb
Page 17
Image 17
DW/CW SERIES (WIDE DYNAMIC RANGE) ADJUSTMENTS

DW/CW SERIES (WIDE DYNAMIC RANGE) ADJUSTMENTS

Refer to Figure 12 to adjust the IS210-DW or IS210-CW model.

SW1 SW1-1: Video Format

DEFAULT SWITCH POSITION

R7

Figure 12. Adjusting the IS210-DW/CW Series Camclosure

SWITCH SETTINGS

Locate the DIP switch. Then set the switches for your installation.

SW1-1: Video Format

Set SW1-1 to ON for NTSC. Set it to OFF for PAL. The default setting is ON.

SW1-2: Line Sync

When multiple cameras are connected to the same switching device, vertical roll may occur on the monitor. AC line lock eliminates vertical roll by locking the frame rate to the power supply frequency. Each camera output is synchronized to the power supply frequency. Refer to Vertical Phase Adjustment on page 20 for more information.

Internal line sync disables line lock and synchronizes cameras internally.

Set SW-1 to ON to use AC line lock. Set it to OFF for internal line sync. The default setting is ON.

SW1-3: Interlaced Scanning/Progressive Scanning

Interlaced scanning is the standard for analog recording installations. Each frame contains one odd and one even field, each processed separately.

Progressive scanning is better for digital recording installations. Each frame is processed as a whole, which results in less blurring and cleaner digital conversion. It also saves storage space on digital video recorders.

Set SW1-3 to ON to select interlaced scanning. Set it to OFF to select progressive scanning. The default setting is ON.

C3428M-A (1/08)