Image 18
SWITCH SETTINGS

SWITCH SETTINGS

Locate the DIP switch (refer to Figure 10). Then set the switches for your installation.

DIP SWITCH

Manual background DOWN UP Manual background

1 2 3 4 5 6Manual backgroundManual background

ON

SWITCH POSITION

Figure 10. DIP Switch

SW1: Video Format

Set to ON for NTSC. Set to OFF for PAL. The default is ON.

SW2: Line Sync

Set to ON to use AC line lock. Set to OFF for internal line sync. The default is ON.

SW3: Interlaced Scanning/Progressive Scanning

Set to ON to select interlaced scanning. Set to OFF to select progressive scanning. The default is ON.

SW4: Auto White Balance (AWB)/Auto Tracking White Balance (ATW)

Set to ON to enable ATW. This is the default.

To manually set and lock the white balance (AWB), power up the unit. Then place a white background in front of the lens and turn SW4 to OFF.

SW5/SW6: Profile

Select the preset profile that best matches your installation:

Profile

Minimum

SW5

SW6

Illumination

 

 

 

General (default)

6.0 lux

ON

ON

Extended shutter

0.5 lux (15 fps)

OFF

ON

Extended dynamic range

3.0 lux

ON

OFF

Fluorescent

3.0 lux

OFF

OFF

General (default): Use for most installations. This profile provides very good general image quality.

Extended shutter: Use for installation that are mostly low light.