VERTICAL PHASE ADJUSTMENT (24 VAC OPERATION ONLY)

Extended dynamic range: Use for extremely high dynamic installations, for example, doorways, entrances, and exits. This profile offers the maximum wide dynamic range.

Fluorescent: Use for any installation with flickering lighting of any kind.

NOTE: If you select the Fluorescent profile, you should enable AC line lock for best results.

VERTICAL PHASE ADJUSTMENT (24 VAC OPERATION ONLY)

When using more than one camera power supply, a brief vertical roll may occur on the monitor when switching from one camera to another.

To eliminate vertical roll, reverse the 24 VAC connections on one camera. If both cameras are connected to the same transformer, this should solve the problem. If the problem still exists, adjust the phase control by synchronizing, or line-locking, the cameras to one another.

ADJUSTING THE VERTICAL PHASE

You may need two people when synchronizing the cameras: one at the camera, the other at the monitor to observe the vertical roll and the effect of any camera adjustments.

To synchronize the cameras:

1.Choose a reference camera to which all other cameras will be phased.

2.Select the camera to synchronize. Use the phase adjustment control (R8) to synchronize the camera to the reference camera (refer to Figure 11). Turn R8 clockwise to increase vertical phase; turn R8 counterclockwise to decrease vertical phase.

3.Each time an adjustment is made, switch back and forth between the camera you are adjusting and the reference camera. Repeat this process as many times as necessary until the roll between the cameras is no longer noticeable.

4.Adjust the phase of all other cameras by repeating steps 2 through 3. Always adjust to the reference camera selected in step 1.

NOTE: The preferred method for camera phase adjustment is to use a dual trace oscilloscope to align the vertical sync pulses of the reference camera to the selected camera(s).

R8 ADJUSTING THE VERTICAL PHASE

Manual background R7 (RESERVED)

Figure 11. Vertical Phase Adjustment

C3406M-D (1/07)

19

Page 19
Image 19
Pelco Not ICS110-CW manual VERTICAL PHASE ADJUSTMENT 24 VAC OPERATION ONLY, Adjusting The Vertical Phase