Pelco PV1016RN Programming a Transmitter Number for Call-up, Dialing a Transmitter Phone Number

Models: PV1016RN

1 4
Download 4 pages 6.29 Kb
Page 2
Image 2

■ Set the DIP switches on the rear of the PV110 modem according to the table below.

PV110 Modem DIP Switch Settings

1

2

3

4

5

6

7

8

ON

ON

OFF

OFF

ON

ON

OFF

OFF

 

 

 

 

 

 

 

 

■ Connect the modem or terminal adapter to the Receiver using the supplied cable. ■ Connect the Receiver to an approved power source.

■ Connect a monitor to either monitor output.

■ Connect phone line(s) and power supply to the modem or terminal adapter.

Programming a Transmitter Number for Call-up

Switch power ON to the Modem/Terminal Adapter first, then turn on the Receiver. The Modem/Terminal Adapter will take a moment to “handshake” with the Receiver before being ready to call a Transmitter. If Receiver and Modem/Terminal Adapter will not successfully handshake, confirm DIP switch settings and/or programming (PV120) are correct.

NOTE

If Receiver and Modem/Terminal Adapter will not handshake after power-up, cycle power and observe the start-up message on the monitor. The PV1016R with the PV110 will display U.S. ROBOTICS DTE SPEED 38,400 as the modem type and speed. The PV1016RN with the PV120 will display PREINITIALIZED DTE SPEED 115,200 as the modem type and speed. If the displayed message is incorrect, re-check the DIP switch settings.

Refer to Figure 2 during the instructions that follow.

From the Receiver front panel, press the PROG (program) key to display the Receiver Status dialog box on the monitor display.

Enter 1234 (default pass code) to display the Programming dialog box.

Using the PAN/TILT keys, move the highlight to Receiver and press the ENTER key to display the main Receiver Program- ming dialog box.

Using the PAN/TILT keys, highlight Directory in the Receiver Programming menu, then press the ENTER key to display the Telephone Directory list. The left side of the Telephone Directory is for entering site names; the right side for entering telephone numbers.

Use the PAN/TILT keys to move around within the Directory menu.

Use the SCROLL keys to increment/decrement through the allowable character set for each character entry.

Enter the Site Name (optional) and phone number of the Transmitter you wish to connect to. Don’t forget to include area code and/or any other access numbers, as necessary.

DIR

LINE

 

 

 

PHONE

 

1

2

DIR

NUMBER

DIAL

 

 

 

DIR

SCROLL

ENTER

 

 

 

VERIFY

 

 

 

3

4

NEW

HIGH WNDO

FREEZ

 

AUXILIARY

 

DISPLAY

 

SCROLL

ENTER

 

NUMBER PAD (1234)

FRONT

 

 

 

 

ZOOM

FOCUS

1

2

3

4

PRESET

 

 

 

 

 

 

POWER

0 1

2

3

4

MODEM

 

5

6

7

8

9

 

 

 

 

 

PROG

 

5

6

7

8

A/B

PAN / TILT

 

 

CAMERA - PRESET

 

 

 

 

 

 

 

RECEIVER

 

 

 

PROG

PAN/TILT

Figure 2. Front Panel

Pelco has made available a toll-free PSTN demonstration number for 24-hour call-up. An ISDN site is available by appointment. Dealers may call Pelco at 1-800-289-9100 to obtain the ISDN demonstration number.

Site

Phone Number

Toll-free PSTN demonstration site

1-888-294-1560

To return to the PelcoVision™ main screen after entering Transmitter phone number(s), press ENTER, move the highlight to Save Changes (you must save the changes), press ENTER, move to Exit, press ENTER, and finally, move to Exit again and press ENTER.

Dialing a Transmitter Phone Number

Press the DIR key (from the PelcoVision™ screen) to display the Telephone directory. Use the NUMBER up/down keys to highlight the entry to be dialed and press DIAL. The Receiver will dial the number and attempt a connection. If successful, the type of connection and baud rate will be displayed on the monitor. If unsuccessful, a reason code will be displayed. See Troubleshooting or section 7.0 in the PelcoVision™ I/O Manual (C1913M).

Page 2
Image 2
Pelco PV1016RN Programming a Transmitter Number for Call-up, Dialing a Transmitter Phone Number, Site Phone Number