Pelco SS3002 operation manual Adjustments, PELCO Manual C428M-B2/98

Models: SS3002

1 16
Download 16 pages 5.84 Kb
Page 11
Image 11
3.5 ADJUSTMENTS

3.5 ADJUSTMENTS

CAUTION: Do not at- tempt to adjust limit stops when pan/tilt is in opera- tion. Damage to the equip- ment can result. Also, do not operate equipment without limit stops. Do not remove or reposition fixed limit stop on the PT280- 24P pan/tilt. DAMAGE WILL OCCUR.

To adjust the pan/tilt limits, perform the following steps. Refer to Figure 6 for limit stop locations.

1.Factory pan limits are set to 0-355°and tilt limits at ±45°. Pan to the right using the joystick control until the desired RIGHT pan limit is reached.

2.Adjust the pan limit stop until the actuator clicks. Lock the limit into position.

3.Pan to the desired left position, adjust the pan limit stop until the actuator clicks, and lock into position.

4.Pan to the left and right to verify exact positioning and tighten both stops se- curely.

5.Remove the left cover plate by removing the two screws for access to the tilt limit stops.

6.Loosen the screws and move the DOWN limit stop to the furthest position. Using the joystick control, tilt the unit to the desired down position.

7.Move the DOWN limit stop until the actuator clicks. Lock the limit into position.

8.Adjust the UP limit stop in the same way.

9.Tilt up and down to verify exact positioning and tighten both stops securely.

Figure 6. PT280-24P Limit Locations

PELCO Manual C428M-B (2/98)

11

Page 11
Image 11