3.0 INSTALLATION

3.0 INSTALLATION

Save the shipping carton and plastic packing in case the unit has to be returned for credit or repair.

3.1 CONDUCTOR AND CABLE REQUIREMENTS

Before installing the pan and tilt, determine the conductor requirements and length of cable you will need to run based on the following:

Conductor requirements for the pan and tilt are as listed below, plus coax cable:

 

Pan/Tilt

Lens

Cam AC

PT280-24P/PT280-24SL

5+ grnd

4

2

PT280-24P/PP

9+ grnd

8

2

PT280-24SL/PP

10+ grnd

8

2

(Camera power, lens functions and video are fed through the input connector on the base of the pan/tilt.)

The following are the cable requirements for the PT280 series pan and tilts:

 

5 Conductor

6 Conductor*

20 Awg

110 ft (33.53m)

210 ft (64.01m)

18 Awg

180 ft (54.86m)

330 ft (100.58m)

16 Awg

290 ft (88.39m)

530 ft (161.54m)

*Using 2 wire common

3.2WIRING INSTRUCTIONS

NOTE: If you are not using the C1906, C1906/PP, C1925, or C1925/

PPpretested cable you must reverse the left/right and up/down function pins as shown in Figure 1.

To install and test the pan/tilt you will need to assemble the connector parts pro- vided. Refer to Section 3.3 for connector assembly.

The PT280 series pan/tilts are prewired for all control functions (pan/tilt, motorized zoom lens, 24 VAC camera power, and video. All connections are made at the input connector, eliminating the need for wiring harnesses made in the field. When using Coaxitron Control Systems, consider using the C1906, C1906/PP, C1925 or C1925/

PPfactory assembled pretested cables which are wired for inverted applications. Wire the control cable per the wiring diagram provided in the PT280 Series Pan/Tilt manual, C324M, for the specific pan/tilt you are using. (The PT280-24P basic pan/ tilt wiring diagram is included in this manual for reference only.)

PELCO Manual C428M-B (2/98)