Pella 803V0102 installation instructions 1ROUGH OPENING PREPARATION

Models: 803V0102

1 12
Download 12 pages 57.54 Kb
Page 2
Image 2
1ROUGH OPENING PREPARATION

YOU WILL NEED TO SUPPLY:

Ř Cedar or Impervious shims/spacers (12 to 20)

Ř 2" galvanized roofing nails (1/4 lb.) Manual background

Ř Closed cell foam backer rod/sealant backer (24 to 32 ft.) Manual background

Ř Pella® SmartFlash™ foil backed butyl window and door flashing tape or equivalent

Ř Pella Window and Door Installation Sealant or equivalent high quality, multi-purpose sealant

(2 to 3 tubes per door)

4&"-"/5

Ř Low expansion, low pressure polyurethane insulating window and door foam sealant - DO NOT use high pressure or latex foams

Ř Pella aluminum sill support or 2 x 4 wood blocking Ř Interior trim and/or jamb extensions (15 to 40 ft.)

FOR MULLION APPLICATIONS: Ř I bar joining connector Manual background

Ř Pella silicone foam tape Ř Mullion end plug (2)

Ř Field applied fins (4 pcs. per unit)

Ř Head drip fin (Vertical Mullion applications only)

TOOLS REQUIRED: Ř Tape measure

Ř Level Manual backgroundManual backgroundManual background Ř SquareManual background Ř Hammer Manual backgroundManual background

Ř Stapler Ř Hacksaw

Ř Sealant gun

Ř Scissors or Utility knife Manual background Ř Screwdrivers Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Ř (#2 Phillips with 8" shaft and small flat blade)Manual background

Ř Rubber mallet Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Ř Drill Manual backgroundManual background

Installation will require two or more persons for safety reasons.

1ROUGH OPENING PREPARATION

A.Confirm the opening is plumb and level. Ensure the bottom of the rough opening does not slope towards the interior.

Note: It is critical the bottom is level.

B.Confirm the door will fit the opening. Measure all four sides of the opening to make sure it is 1/2" larger than the door in width and height. Measure the width at the top, bottom and center. Measure the height at the far left side, the far right side and in the center.

Note: Solid wood blocking of 1-1/2" or more is required around the perimeter of the opening. Fix any problems with the rough opening before proceeding.

Manual backgroundManual background*OUFSJPS 1A"Manual background

Manual background*OUFSJPS 1B#Manual background

C.Cut the water resistive barrier.

Water Resistive Barrier

Manual backgroundManual background1st cut

Manual background3rd cut 1C Manual background

Manual backgroundManual background 2nd cut

4th cut:

Make a 6" cut up from each top corner at a 45o angle to allow the water resistive barrier to be lapped over the fin at the head of the door.

Page 2