5REINSTALL THE VENT PANEL - OX/XO DOORS ONLY

5REINSTALL THE VENT PANEL - OX/XO DOORS ONLY

Note: If the optional Patio Door High Performance Panel Retainer was ordered with the sliding door, install the high performance roller retainer before installing the vent panel. Follow the instructions included with the parts.

TWO OR MORE PEOPLE WILL BE REQUIRED TO HANDLE THE PANEL SAFELY.

A.Insert door panel. From the exterior of the building, tilt the top of the panel toward the door frame and insert the top of the door panel into the top track. Move the bottom of the panel toward the door frame until it is vertical. Gently set the panel down into the bottom track.

Note: Be careful not to pinch your fingers between the two panels.

B.Install the handles. Follow the instructions included in the hardware box.

5A"

C.Install the bumpers and retainer. Follow the instructions attached to the parts bag.

D.Check door operation. Open and close the door a few times to check for proper operation.

Note: If there are any problems with the operation of the door, recheck shim locations and adjust for plumb and square.

E.Install screen. Use the screen instructions included with the screen door.

6INTERIOR SEAL

Caution: Ensure use of low expansion polyurethane window and door installation foams and strictly follow the foam manufacturer’s recommendations for application. Use of high expansive foams or improper application of the foam may cause the door to bow and hinder operation.

A. Apply insulating foam sealant. From the interior, insert

the nozzle of the applicator approximately 1" deep into

 

the space between the door and the rough opening and

 

apply a 1" deep bead of foam. This will allow room for

 

expansion of the foam and will minimize squeeze out.

 

Apply sealant across interior surface of shims to create

 

a continuous seal. For windows with jamb extensions

 

installed, ensure the foam is placed between the

6A"

window frame and the rough opening, not between the

 

jamb extension and the rough opening. Follow foam

 

manufacturer's instructions.

 

Note: It may be necessary to squeeze the end of the tube with pliers to be able to insert into the space between the window frame and the rough opening. DO NOT completely fill the space from the back of the fin to the interior face of the opening.

B. Check the door operation by opening and closing the door.

Note: If the door does not operate correctly, check to make sure it is still plumb, level, square and that the sides are not bowed. If adjustments are required, remove the foam with a serrated knife. Adjust the shims, and reapply the insulating foam sealant.