Pentair 620001 Save These Instructions, Alternate Repair Instructions, Step, hn-11-11-16-98

Models: 620001

1 16
Download 16 pages 957 b
Page 16
Image 16
hn-11-11-16-98

Alternate Repair Instructions

STEP 8

1.Completely cover the entire entry hub and the jumper wire connection with two parts of underwater epoxy putty, (supplied with this kit), to at least 1/4 inch thickness.

a.If a jumper wire is connected to the bonding lug in the fixture housing cover this connection with a listed potting compound, (Scotchcast 2134 or equivelant).

b.This will require the pool water level to be lowered and the potted area dried.

c.Allow 30 minutes prior to applying the epoxy putty.

2.Do not cover the anode block.

3.Allow the light fixture cord to move freely within the putty.

NOTE

Cord must move freely within the putty to allow the removal of the light fdixture should it ever need repair or replacement.

Do not cover anode block with potting compound.