Pentair 620001 Section Ii. Alternate Repair Instructions, Before, Step, hn-01-11-16-98

Models: 620001

1 16
Download 16 pages 957 b
Page 9
Image 9
SECTION II. ALTERNATE REPAIR INSTRUCTIONS, BEFORE 1998.

SECTION II. ALTERNATE REPAIR INSTRUCTIONS, BEFORE 1998.

This repair procedure can be used both for small fixture housings and for those with angled conduit hubs.

STEP 1.

Before starting repair, ensure that the inside of the fixture housing has the same style entry hub as shown in Figure 1. It is necessary to verify the correct style entry hub for this warranty repair. The hub may be at the top on the large radius of the fixture housing (45 degree entry), or assembled to the small fixture housing. Before continuing, ensure the conduit entry hub matches Figure 1.

Do not attempt the repair on any fixture housing with any other style entry hub. Even if another type fixture housing shows the same staining, it is likely to be caused by another problem. In that case this procedure will not work and the repair will not be covered by warranty.

Three posts on a ring with the hub lip formed over the edge of the ring I.D.

hn-01-11-16-98

Figure 1.

Rev. A 1-18-06

9

P/N 620001

Page 9
Image 9
Pentair 620001 important safety instructions Section Ii. Alternate Repair Instructions, Before, Step, hn-01-11-16-98