Fixture Housing Entry Hub Repair Instructions.

Fixture Housing Entry Hub Repair Instructions.

STEP 5.

1.Attach an anode block, (with an allen head set screw), installed directly to one of the two unused posts on the hub ring.

a. This is done by pushing the center hole of the block firmly and completely over the post, press-fitting it into place.

2.Position the anode to clear the fixture cord with its rounded edge pointed away from the center of the conduit entry, see Figure 5.

hn-04-11-16-98

Figure 5.

P/N 620001

6

Rev. A 1-18-06