Working with muriatic acid can be dangerous. When cleaning elements always wear rubber gloves and eye protection. Add acid to water, do not add water to acid. Splashing or spilling acid can cause severe personal injury and/or property damage.

Fixture Housing Entry Hub Repair Instructions.

STEP 4

Manual backgroundWARNING

Working with muriatic acid can be dangerous. When cleaning elements always wear rubber gloves and eye protection. Add acid to water, do not add water to acid. Splashing or spilling acid can cause severe personal injury and/or property damage.

1.Completely clean the fixture housing, the light fixture and the pool wall of all of the brown/black staining. The stain can be removed by brushing the stained area with a stainles steel pool brush.

a. For stubborn stains, treat the stained area with a mild solution of muriatic acid and water (1:5 ratio).

2.Remove any excess plaster that may be around the entry hub area of the fixture housing.

Remove all staining from the entry hub, fixture housing, and light fixture.

hn-01-11-16-98

Figure 4.

Rev. A 1-18-06

5