Fixture Housing Entry Hub Repair Instructions.

Fixture Housing Entry Hub Repair Instructions.

STEP 2

1.Ifthereisnointernalbondwireasshown,skiptoSTEP3.

2.Ifthereisaninternalbondwireoranon-listedpottingmaterialaroundthebondpost,removethepottingmaterial completely.Anon-listedpottingmaterialwouldbesilicone,RTV,etc.

a. Be very careful not to damage the No. 8 bond wire, the screw or the post.

3.Replacethebondwireorthebondingscrewifitisdamaged.ThengotoinstructionSTEP4andcompletethe procedures through STEP 6.

Light Fixture

Cord

Internal Bond

Wire

Remove bonding lug potting material if present, check that screw is tight.

hn-02-11-16-98

Fixture 2.

Rev. A 1-18-06

3