Alternate Repair Instructions

Alternate Repair Instructions

STEP 2

Manual backgroundWARNING

Working with muriatic acid can be dangerous. When cleaning elements always wear rubber gloves and eye protection. Add acid to water, do not add water to acid. Splashing or spilling acid can cause severe personal injury and/or property damage.

1.If there is no internal bond wire as shown, skip to STEP 6.

2.If there is an internal bond wire with a non-listed potting material around the bond post, remove the potting material completely. A non-listed potting material would be silicone, RTV, etc.

a. Be very careful not to damage the No. 8 bond wire, the screw or the post.

3.Replace the bond wire or the bonding screw if it is damaged. Then, go to instruction STEP 3 and complete the procedures through STEP 5.

Light Fixture

Cord

Internal Bond

Wire

Remove bonding lug non-listed potting material if present, check that screw is tight.

hn-02-11-16-98

Fixture 2.

P/N 620001

10