ELECTRICAL

Installation (contd.)

17

 

 

ELECTRICAL

MiniMax® CH Millivolt Wiring Diagram

MINIMAX® WIRING DIAGRAM (MILLIVOLT) DUAL THERM (HONEYWELL ELECTRONIC)

IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 105 C˚ TEMPERATURE RATING. THERMAL FUSE WIRING MUST BE REPLACED WITH UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 125 C˚ TEMPERATURE RATING. INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO THE NATIONAL ELECTRICAL CODE OR SUPERCEDING LOCAL (WIRING) CODES.

 

 

PILOT

 

 

TH/PP

WHT

GENERATOR

 

 

 

 

 

 

RED

 

 

 

TH

PP

 

SAFETY

PRESS

GAS VALVE

 

 

 

HI-LIMIT

SHUT-OFF

SWITCH

 

 

WHT

 

WHT

WHT

WHT

THERMAL

CUT-OFF

ORN

WHT

WHT

TH/PP

PP

TH

POT 1

POT 2

THERMOSTAT BOARD

SEN

POT

 

SENSOR

POOL

OFF

SPA

Figure 19.

NOTE: When connecting a remote control to the MiniMax® CH, you must install the low voltage thermostat wires in separate conduit from ANY line voltage wires. Failure to follow these instructions will cause the thermostat relay to react erratically.