Call 800 831-7133 for additional free copies of these instructions
Attention Installer
Attention User
2007 Pentair Water Pool and Spa, Inc. All rights reserved
FOR YOUR SAFETY - READ BEFORE OPERATING
POOL & SPA HEATERS OPERATION & INSTALLATION MANUAL
For Your Safety
MiniMax CH
Table of Contents
Pool and Spa Heaters
MiniMax CH
Introduction
CODE REQUIREMENTS
Operation
WARRANTY INFORMATION
SAFETY RULES
PRODUCT IDENTIFICATION
LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
MINIMAX CH MILLIVOLT LIGHTING/OPERATION-NATURAL GAS & PROPANE
TO TURN OFF GAS TO HEATER
POWER THERMOSTAT SELECT SWITCH
Dual Temperature Control System
THERMOSTAT ADJUSTMENT
OPERATING CONTROLS
ENERGY SAVING TIPS
Maintenance
MAINTENANCE INSTRUCTIONS
SPRING AND FALL OPERATION
CHEMICAL BALANCE
pH Chart
pH Control Chart
Pool and Spa Water
Outdoor installation - stackless
Installation Instructions
SPECIFICATIONS
Outdoor installation - with vent kit
PLUMBING CONNECTIONS
BELOW POOL INSTALLATION
BELOW OR ABOVE POOL INSTALLATION
PLUMBING
INSULATING THE HIGH LIMITS
When Reversing Heads on the MiniMax CH Heater
WATER CONNECTIONS
Reversible Inlet/Outlet Connection
GAS LINE INSTALLATIONS
GAS CONNECTIONS
PROPANE 2 STAGE REGULATION
REGULATED MANIFOLD PRESSURE TEST
MINIMAX CH GAS PRESSURE REQUIREMENTS
Stage One High Pressure Gas Pipe Sizing
VENTILATION
OUTDOOR INSTALLATION ONLY
OUTDOOR VENT CAP INSTALLATION
STACK TYPE OUTDOOR VENT KIT
INDOOR INSTALLATION USA ONLY OUTDOOR SHELTER INSTALLATION CANADA
Air supply requirements below apply to all MiniMax heaters
INDOOR DRAFT HOOD INSTALLATION
STACK TYPE INDOOR DRAFT HOOD KIT
All opening sizes are minimum and unobstructed
MINIMAX WIRING DIAGRAM MILLIVOLT DUAL THERM HONEYWELL ELECTRONIC
MiniMax CH Millivolt Wiring Diagram
ELECTRICAL
Installation contd
Troubleshooting - General
Defective hi-limit and/or thermostat
Model No. Part No
MINIMAX CH HEATER - ALL MODELS
INNER TOPS
470024
MiniMax CH Parts List
DESCRIPTION
Not Shown
MiniMax CH Parts List, contd
DESCRIPTION
Rev. E
For Your Safety
POOL & SPA HEATERS OPERATION & INSTALLATION MANUAL APPENDIX
MiniMax CH 150 IID Model
FOR YOUR SAFETY - READ BEFORE OPERATING
FOR YOUR SAFETY READ BEFORE LIGHTING
OPERATING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
WHAT TO DO IF YOU SMELL GAS
FOR YOUR SAFETY READ BEFORE LIGHTING
Safety Lockout
MINIMAX CH 150 IID ELECTRONIC IGNITION LIGHTING/OPERATION - PROPANE
OPERATING INSTRUCTIONS
THERMOSTAT ADJUSTMENT
INDICATOR LIGHT DESCRIPTION
Dual Temperature Control System - Electronic and Millivolt Models
POWER THERMOSTAT SELECT SWITCH
HEAT HEAT
TROUBLESHOOTING CONTROLS
SERVICE SERVICE
Rev. E
TROUBLESHOOTING CONTROLS - Continued
Operation contd
THERMOSTAT CIRCUIT BOARD HEATER FIRING - NORMAL OPERATION
REGULATED MANIFOLD PRESSURE TEST
ELECTRICAL, IID ELECTRONIC UNITS
Installation contd
Electronic Ignition Wiring
Diagram
MiniMax CHMiniMax150 IIDPlusWiringWIRINGDiagramDIAGRAM
THERMOSTAT CIRCUIT BOARD
INNER TOP
MINIMAX CH HEATER - 150 IID MODEL
A-10
Model No. Part No
A-11
MiniMax CH Parts List - 150 IID Model
DESCRIPTION
Not Shown
MiniMax CH Parts List - 150 IID Model, contd
DESCRIPTION
A-12
A-13
Rev. E
Rev. E
SAVE THESE INSTRUCTIONS
2007 Pentair Water Pool and Spa, Inc. All rights reserved
1620 Hawkins Ave., Sanford, NC 27330 800 831-7133 or 919
Pour Votre Sécurité
POUR PISCINE ET THALASSO MANUEL DE MONTAGE ET DE FONCTIONNEMENT
AVERTISSEMENT
QUE FAIRE EN CAS D’ODEUR DE GAZ ?
Equilibre chimique
Table des Matières
Garantie
Déviation manuelle
EXIGENCES LÉGALES
CHAUFFE-EAU MINIMAX CH
Pour Piscines et Thalassos
CONSIGNES IMPORTANTES…
GARANTIE
Fonctionnement
AVERTISSEMENT
CONSIGNES DE SÉCURITÉ
FEMER L’ARRIVÉE DU GAZ VERS L’APPAREIL
POUR VOTRE SÉCURITÉ LIRE ATTENTIVEMENT AVANT D’ALLUMER
CONSIGNES DE FONCTIONNEMENT
AVERTISSEMENT
MANETTE DE VERROUILLAGE DU THERMOSTAT
FONCTIONNEMENT CONTRÔLES
Système de contrôle bi-température
AJUSTEMENT DU THERMOSTAT
FONCTIONNEMENT EN HIVER
CONSIGNES DE MAINTENANCE
FONCTIONNEMENT EN AUTOMNE ET AU PRINTEMPS
CONSEILS POUR ÉCONOMIES D’ÉNERGIE
EAU DE PISCINE ET DE THALASSO
Maintenance suite
ÉQUILIBRE CHIMIQUE
L’EFFET D’UN DÉSINFECTANT
CONSIGNES DE MONTAGE
Installation en extérieur - sans cheminée
Installation en extérieur - avec kit de ventilation
CARACTÉRISTIQUES
INSTALLATION AU-DESSUS OU EN-DESSOUS DU NIVEAU DE LA PISCINE
INSTALLATION SOUS LA PISCINE
Installation suite
PLOMBERIE
Lors de l’inversion des têtes sur le chauffe-eau MiniMax CH
RACCORDS D’ARRIVÉE D’EAU
ISOLER LES HAUTES LIMITES
Branchement réversible entrée/sortie
Installation suite
INSTALLATIONS DE LA CONDUITE DE GAZ
RACCORD DE GAZ
AVERTISSEMENT
RÉGULATION DU PROPANE EN DEUX PHASES
TEST PRÉ-RÉGLÉ DE PRESSION MULTIPLE
EXIGENCES POUR LA PRESSION DU GAZ DU MINIMAX CH
Installation suite
INSTALLATION DU CAPOT DE VENTILATION EXTÉRIEUR
INSTALLATION EN EXTÉRIEUR UNIQUEMENT
Installation suite
VENTILATION
Arrière
Côté
Face
Sommet
Les exigences pour l’approvisionnement d’air ci
INSTALLATION SUR DES SOLS COMBUSTIBLES
Installation suite À NOTER
Installation suite
SYSTÈME ÉLECTRIQUE
ORGANIGRAMME DES CIRCUITS À MILLIVOLTMÈTRE DU MINIMAX CH
WIRE COLOR CODE
Nettoyer le filtre et le filtre de la pompe
Détection de pannes - Général
Commutateur ON/OFF en position OFF
Haute limite et/ou thermostat défaillant
Modèle No. Part No
CHAUFFE-EAU MINIMAX CH - TOUT MODÈLE
Couvercles Intérieurs
470024
Montage du plateau de brûleur de gaz naturel complet - millivoltmètre
Liste des Pièces du MiniMax CH
DESCRIPTION
Montage du plateau de brûleur de propane complet - millivoltmètre
Sans Illustration
Liste des Pièces du MiniMax CH suite
DESCRIPTION
Rev. E
Remarques
P/N 472128 Fr
MiniMax CH 150 IID Model
APPENDICE AVERTISSEMENT
POUR VOTRE SÉCURITÉ LIRE ATTENTIVEMENT AVANT LA MISE EN MARCHE
AVERTISSEMENT
Fonctionnement
CONSIGNES DE FONCTIONNEMENT
FERMER L’ARRIVÉE DU GAZ VERS L’APPAREIL
AVERTISSEMENT
AVERTISSEMENT
REMARQUE
Verrouillage de sécurité
POUR VOTRE SÉCURITÉ LIRE ATTENTIVEMENT AVANT D’ALLUMER
VERROU DU CADRAN DE RÉGLAGE DU THERMOSTAT
VOYANT D’ALIMENTATION POWER
DESCRIPTION DES VOYANTS LUMINEUX
RÉGLAGE DU THERMOSTAT
PRESSOSTAT PRESS
ENTRETIEN SERVICE
DÉPANNAGE CONTRÔLES
CHALEUR HEAT
P/N 472128 Fr
DÉPANNAGE CONTRÔLES - Suite
Fonctionnement suite
Rev. E
Classement électrique
VÉRIFICATION DE LA PRESSION D’ADMISSION CONTRÔLÉE
ÉLECTRIQUE, UNITÉS ÉLECTRONIQUES IID
AVERTISSEMENT
Schéma de câblage du MiniMax CH Modèle 150 IID
Schéma d’allumage électronique du MiniMax CH Modèle
Installation suite
P/N 472128 Fr
COMMANDE À DISTANCE À DEUX FILS
COMMANDE À DISTANCE À DEUX THERMOSTATS IID UNIQUEMENT
COMMANDE À DISTANCE À SORTIE TROIS FILS
Installation suite
COUVERCLE INTÉRIEUR
CHAUFFE-EAU MINIMAX CH - MODÈLE 150 IID
A-10
No. de
Liste des pièces de remplacement pour le MiniMax CH - Modèle 150 IID
ARTICLE
P/N 472128 Fr
Remarques
Rev. E
1620 Hawkins Ave., Sanford, NC 27330 800 831-7133 ou 919
CONSERVEZ CES CONSIGNES EN LIEU SÛR
2007 Pentair Water Pool and Spa, Inc. Tous droits réservés
10951 West Los Angeles Ave., Moorpark, CA 93021 800 831-7133 ou 805
ADVERTENCIA
CALENTADORES PARA PISCINA Y SPA
MANUAL DE INSTALACIÓN Y OPERACIÓN ADVERTENCIA
Por su Seguridad
Conexiones para tubería
Contenido
Especificaciones
Conexiones para el gas
PRECAUCIÓN
Introducción
CALENTADORES MINIMAX CH PARA PISCINA Y SPA
REQUERIMIENTOS DE CÓDIGOS
IDENTIFICACIÓN del PRODUCTO
Operación
INFORMACIÓN DE GARANTÍA
NORMAS DE SEGURIDAD
¿CÓMO DESCONECTAR EL GAS DEL CALENTADOR?
LEA ANTES DE ENCENDER POR SU SEGURIDAD
INSTRUCCIONES DE ENCENDIDO
ADVERTENCIA
PERILLA PARA DETENER EL TERMOSTATO
OPERACIÓN CONTROLES
Sistema Dual de Control de Temperatura
REGULACIÓN DEL TERMOSTATO
OPERACIONES DURANTE INVIERNO
Mantenimiento
OPERACIONES DURANTE LA PRIMAVERA Y OTOÑO
INSTRUCCIONES DE MANTENIMIENTO
Mantenimiento contd
BALANCE QUÍMICO
AGUA DE PISCINAS Y SPA
¿Qué hace el desinfectante?
Instalacion Externa - sin chimenea
Instrucciones de Instalación
ESPECIFICACIONES
Instalación Externa - con kit de ventilación
BY-PASS MANUAL
CONEXIONES PARA LA TUBERÍA
TUBERÍAS
VÁLVULAS
Conexión intercambiable de entrada y salida
CONEXIONES PARA EL AGUA
AISLAMIENTODELOSLÍMITESALTOS
Al Intercambiar los Cabezales del Calentador MiniMax CH
Instale externamente la válvula principal shut-off al calentador
CONEXIONES PARA GAS
INSTALACIONES LINEALES PARA GAS
ADVERTENCIA
REGULACIÓN DEL PROPANO DE DOS FASES
PRUEBA DE PRESION DEL COLECTOR REGULADO
REQUERIMIENTOS PARA LA PRESIÓN DE GAS MINIMAX CH
Natural
INSTALACIÓNDELCASCODEVENTILACIÓNEXTERNO
VENTILACIÓN
SÓLO INSTALACIÓN EXTERNA
KIT DE VENTILACIÓN EXTERNA TIPO CHIMENEA
INSTALACIÓN INTERNA sólo para EEUU
INSTALACIÓN PARA PROTECCIÓN EXTERNA CANADA
INSTALACIÓN SOBRE SUELOS HECHOS CON MATERIAL COMBUSTIBLE
KIT DE CAMPANA LATERAL INTERNA TIPO CHIMENEA
INSTALACIÓN INTERNA DE LA CAMPANA LATERAL
Instalación contd NOTA
VÁLVULA DE GAS
ELECTRÓNICA
CIERRE DE
LÍMITE ALTO
PRECAUCIÓN
Soluciónes para diferentes problemas - General
Cuando el calentador siga operando
470028
CALENTADOR MINIMAX CH- TODOS LOS MODELOS
TAPA INTERNA Modelo No. de Partes 150 200 250 300
470029
Rev. E
LISTA DE PARTES DEL MINIMAX CH
P/N 472128 Sp
P/N 472128 Sp
LISTA DE PARTES DEL MINIMAX CH, contd
Rev. E
Rev. E
NOTAS
P/N 472128 Sp
MANUAL DE INSTALACIÓN Y OPERACIÓN APENDICE ADVERTENCIA
MiniMax CH 150 IID Modelo
CALENTADORES PARA PISCINA Y SPA
ADVERTENCIA
Operación
INSTRUCCIONES DE OPERACIÓN
CÓMO DESCONECTAR EL GAS DEL ARTEFACTO
¿Qué hacer cuando huele a gas?
INSTRUCCIONES DE OPERACIÓN
Cierre de seguridad
LEA ANTES DE ENCENDER POR SU SEGURIDAD
CÓMO DESCONECTAR EL GAS DEL ARTEFACTO
OPERACIÓN CONTROLES
DESCRIPCIÓN DE LUCES INDICADORAS
POWER LIGHT POWER
Operación contd
CALOR HEAT
SERVICIO SERVICE
INDICADOR DE DEFECTOS CONTROLES
Operación contd
P/N 472128 Sp
INDICADOR DE DEFECTOS CONTROLES , CONTD
Operación contd
Rev. E
ADVERTENCIA
PRUEBA DE PRESIÓN MÚLTIPLE REGULADA
ELECTRÓNICA, IID UNIDADES ELECTRÓNICAS
Diagrama del Cableado MiniMax CH Modelo 150 IID
Diagrama de cableado de ignición electrónica MiniMax CH Modelo
150 IID
472128 Sp
PRESIÓN ALTO FUSIBLE T VÁLVULA MÓDULO DE IGNICIÓN
LÍMITE
24 VAC
LÍMITE 24 VAC PRESIÓN ALTO FUSIBLE T VÁLVULA MÓDULO DE IGNICIÓN
P/N 472128 Sp
CALENTADOR MINIMAX CH - MODELO 150 IID
A-10
Rev. E
Lista de partes del MiniMax CH - Modelo 150 IID
CALENTADOR MINIMAX CH - MODELO 150 IID, contd
Rev. E
NOTAS
A-13
P/N 472128 Sp
2007 Pentair Water Pool and Spa, Inc. Todos los derechos reservados
CONSERVE ESTAS INSTRUCCIONES
Este documento está sujeto a cambios sin previo aviso
1620 Hawkins Ave., Sanford, NC 27330 800 831-7133 o 919
Call 800 831-7133 for additional free copies of these instructions
Attention Installer
Attention User
2007 Pentair Water Pool and Spa, Inc. All rights reserved