Installing the Cell Assembly
Install the IntelliChlor cell assembly no closer than three (3) feet from the heater outlet, if used. For more information see plumbing diagrams on page 3 and 4.
Note: After new pool construction has been completed, in order to prevent debris from entering the IntelliChlor cell assembly, it is recommended that the IntelliChlor
Note: Pipe couplings: Schedule 80, maximum pressure 75 psi to 70° F
Coupling
Coupling
To install the cell:
1.Using PCV glue, mount the PVC couplings to the plumbing pipe. Allow the glue to dry.
2.Mount the cell to allow access to the control panel. Install the cell onto the couplings. Ensure the
3.Switch on the pump and visually inspect for leaks around the couplings.
Connecting the Cell Power Cable to the Power Center
After the cell installation is completed, connect the power cable to the Power Center:
•Align the four pins of the cell power cord connector with the socket on the bottom of the Power Center and insert the connector. Turn the round socket nut until it locks the connector in place.
Connector socket nut.
To cell assembly