Connecting IntelliChlor to an IntelliTouch System

20

Connecting IntelliChlor to an IntelliTouch System

To connect the four wire cable communication from the IntelliChlor Power Center (see page 19) to the Personality board located in the IntelliTouch load center:

Personality BoardWARNING Switch OFF main system power to the Load Center before making any connections.

1.Unlatch the load center enclosure door spring latches, and open the door.

2.Loosen the two retaining screws from the Outdoor Control Panel.

3.Lower down the Outdoor Control Panel on its hinges to access the Personality board located behind the Outdoor Control Panel.

4.Route the four conductor cable up through the low voltage raceway in the Load Center to the Personality board.

5.Strip back the cable conductors ¼ in. Insert the wires into the screw terminals (provided in the kit). Secure the wires with the screws. Make sure to match the color coding of the wires; Red = +15, Yellow = +DT, Green = -DT, and GND = Black.

6.Insert the cable plug onto either of the COM PORTS (J7 or J8) connectors located on the left side of the Personality board.

7.When the connection has been completed, close the control panel into its original position and secure it with the two retaining screws.

8.Close the load center front door. Fasten the two spring latches.

9.Restore AC power to the system.

Retaining screws

Personality board

Outdoor

Control

Panel

COM ports

BLK

GRN

YEL

RED

Personality board

(Connector J7 or J8)

Personality Board

Route wire from IntelliChlor into conduit knockout up through raceway to Personality board

IntelliTouch Load Center