Pentair IC20, IC40 Section, Installation, Kit Contents, Required Tools

Models: IC20, IC40

1 32
Download 32 pages 27.03 Kb
Page 23
Image 23
Section 4

17

Section 4

Installation

This section describes how to install the IntelliChlor electrolytic cell assembly into the pool plumbing system. Also, included are connection instructions for IntelliTouch and EasyTouch systems. Before installing, review the IntelliChlor kit contents and required tools.

Note: For Power Center installation instructions, see the “IntelliChlor Power Center Installation Guide” (P/N 520590).

Note: Salt is not provided. For details about the type of salt to use, see “What type of salt to use,” on page 13.

Kit Contents

-One electrolytic cell

-Two cell union with two o-rings

-User’s Guide (this manual)

Required Tools

-Tape measure

-Phillips and flathead screwdriver

-Pliers

-Hacksaw

-An NSF® approved all purpose PVC/CPVC/ABS cleaner primer

-An NSF® approved all purpose PVC/CPVC/ABS cement

InstallationWARNING! When using electrical products, basic precautions should always be followed, including the following:

DANGER: RISK OF ELECTRIC SHOCK,WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before attempting installation of service, ensure that all power to the circuit supplying power to the system is disconnected/turned off at the circuit breaker. It is recommended, but not mandatory that the IntelliChlor Power Center be connected to a circuit protected by a ground fault circuit-interrupter (GFCI).

Grounding (earth bonding) is required. The unit should be installed by a qualified service person and grounded.

Install to allow access to cell buttons and power center.

Read Safety Precautions and Important Instructions (page ii and iii). Before attempting any electrical wiring, be sure to read and follow Safety Instructions. Wiring should only be performed by a qualified professional.

Install the IntelliChlor unit a minimum of two (2) feet from the heater outlet.

Pipe couplings: Schedule 80, maximum pressure 150 psi at 70° F.

Note: Operate unit with minimum flow of 20 gpm. For high flow applications, use a bypass loop.

IntelliChlor Installation and User’s Guide

Page 23
Image 23