P/N 520050 12 Rev. F 3-26-04
VALVE ACTUATORS
Remove knob, handle and four screws from cap of valve(s) to be motorized, and use the four mounting screws
provided to mount Valve Actuator(s) to valve(s).
Run cables to low-voltage wiring compartment of LX-100 RF Power/Load Center, and plug into circuit board at the
appropriate Valve Socket:
Plug intake (suction) valve into INT VLV Socket.
Plug return valve into RET VLV Socket.
Plug auxiliary valve (if applicable) into AUX VLV Socket.
RECEIVER ANTENNA CAUTION
Antenna must be attached with o-ring for proper functioning. Not installing o-ring can lead
to damage of LX-100 RF Power/Load Center.
Slide orange o-ring over threaded antenna connector protruding from top of the
LX-100 RF Power/Load Center.
Screw on antenna until it stops. O-ring should be compressed by antenna.
INTAKE
VALVE
ACTUATOR ACTUATOR
VALVE
RETURN AUXILIARY
VALVE
ACTUATOR
VLV
AUX
VLV
VLV
RET
24
18 0
INT
MOTOR SWITCH
FLTR TIMER
MOTOR SWITCH
CLNR TIMER
COMPOOL
11056
PART#:PC-LX100
LX-100 RF POWER/LOAD CENTER
ENCLOSURE