Pentair 40106 Rev. H 05/05 General Service Hints for Meter Control, Backwash position, Problem

Models: 40106 Rev. H 05/05 Model 5600 & 5600 Econominder

1 36
Download 36 pages 13.06 Kb
Page 30
Image 30
Backwash position.

Model 5600 & 5600 Econominder®

Model 5600 and 5600 Econominder Troubleshooting (Cont’d.)

 

PROBLEM

 

CAUSE

 

CORRECTION

 

 

 

 

 

9.

Softener fails to draw brine.

A.

Draw line flow control is plugged.

A. Clean drain line flow control.

 

 

B.

Injector is plugged.

B.

Clean or replace injectors.

 

 

C.

Injector screen plugged.

C.

Replace screen.

 

 

D.

Line pressure is too low.

D.

Increase line pressure (minimum 20

 

 

 

 

 

psi at all times).

 

 

E.

Internal control leak.

E. Change seals, spacers and/or piston

 

 

 

 

 

assembly.

10.

Control cycles continuously.

A.

Faulty timer mechanism.

A.

Replace timer.

11.

Drain flows continuously.

A.

Foreign material in control.

A.

Remove piston assembly and inspect

 

 

 

 

 

bore, remove foreign material and

 

 

 

 

 

check control in various regeneration

 

 

 

 

 

positions.

 

 

B.

Internal control leak.

B. Replace seals and/or piston assembly.

 

 

C.

Control valve jammed in Brine or

C.

Replace seals and/or piston assembly.

 

 

 

Backwash position.

 

 

 

 

D.

Timer motor stopped or jammed.

D.

Replace timer.

 

 

 

 

 

 

General Service Hints for Meter Control

PROBLEM

 

CAUSE

CORRECTION

 

 

 

 

Softener delivers hard water.

A.

Reserve capacity has been exceeded.

A. Check salt dosage requirements and

 

 

 

reset program wheel to provide

 

 

 

additional reserve.

 

B. Program wheel is not rotating with meter

B. Pull cable out of meter cover and

 

 

output.

rotate manually, program wheel

 

 

 

must move without binding and

 

 

 

clutch must give positive "clicks"

 

 

 

when program wheel strikes

 

 

 

regeneration stop (if not, replace

 

 

 

timer).

 

C.

Meter is not measuring flow.

C. Check output by observing rotation

 

 

 

of small gear on front of timer

 

 

 

(program wheel must not be against

 

 

 

regeneration stop for this check)

 

 

 

each tooth to tooth is approximately

 

 

 

30 gallons (if not, replace meter).

30