Model 5600 & 5600 Econominder®

Model 5600 Backwash Filter Installation and Start-up Procedures (Cont’d.)

Cycle Times and Flow Diagrams

1.In Service position. See Figure 4, page 10.

2.Preliminary Rinse position.

Same as Figure 4, page 10 with standard piston (white end plug) or filter piston (black end plug).

Eliminated with low water piston (gray end plug).

3.Backwash position.

Same as Figure 6, page 11 with standard piston.

15 minutes with filter piston.

7 minutes with low water piston.

4.Brine Rinse position.

Eliminated, resulting in a 50 minute pause, no water flows during this time.

5.Slow Rinse position.

Eliminated, resulting in a 50 minute pause, no water flows during this time.

6.Second Backwash position.

Same as Figure 9, page 12 with standard piston.

15 minutes with filter piston.

7 minutes with low water piston.

7.Settling Rinse position.

Same as Figure 10, page 13 with standard or filter piston.

Eliminate with low water piston.

8.Brine Tank Refill position.

Eliminated, filter is back in service at this time.

8

Page 8
Image 8
Pentair 40106 Rev. H 05/05, Model 5600 & 5600 Econominder manual Cycle Times and Flow Diagrams, Preliminary Rinse position