Model 5600 & 5600 Econominder®

Model 5600 Installation and Start-up Procedures

NOTE: Install the water softener with the inlet, outlet and drain connections made according to manufacturer’s recommendations and to meet applicable plumbing codes.

Manual

 

Regeneration Knob

24-Hour Gear

 

Skipper Wheel

Red Time

(shows every

Set Button

other day

 

regeneration)

Time of Day Arrow

Red Pointer

Figure 1: Model 5600 Softener Control

1.Manually index the softener control into the In Service position and let water flow into the resin tank. When the water flow stops, open a softened water tap until all air is released from the lines. Then close tap.

NOTE: Manually dial the various regeneration positions by turning the knob on the front of the control until the indicator shows that the softener is in the desired position.

2.Manually index the control to the Backwash position and allow water to flow at the drain for 3 or 4 minutes.

3.Remove back cover plate.

4.Make sure that the salt dosage is set as recommended by the manufacturer. If necessary, set salt according to the setting instruction sheet. Manually index the control to the Brine Fill position and allow the brine tank to fill to the top of the air check.

5.Manually index the control to the Brine Draw position and allow the control to draw water from the brine tank until it stops.

6.Plug in the electrical cord and look in the sight hole in the back of the motor to see that it is running. Set the days that regeneration is to occur by sliding tabs on skipper wheel outward to expose trip fingers.

Each tab is one day.

Finger at red pointer is tonight.

Moving clockwise from red pointer, extend or retract fingers to obtain the desired regeneration schedule.

7.Manually advance the control to the beginning of the Brine Fill position and allow the control to return to the In Service position automatically.

8.Fill the brine tank with salt.

9.Replace back cover on the control.

10.Make sure that any bypass valving is left in the normal In Service position.

6

Page 6
Image 6
Pentair 40106 Rev. H 05/05 manual Model 5600 Installation and Start-up Procedures, Model 5600 Softener Control