PROBLEM

 

CAUSE

 

CORRECTION

 

 

 

 

 

 

1.

Softener fails to regenerate.

A.

Electrical service to unit has been

A.

Assure permanent electrical service

 

 

 

interrupted.

 

(check fuse, plug, pull chain or

 

 

 

 

 

switch).

 

 

B.

Timer is defective.

B.

Replace timer.

 

 

C.

Power failure.

C.

Reset time of day.

 

 

 

 

 

 

2.

Softener delivers hard water.

A.

Bypass valve is open.

A.

Close bypass valve.

 

 

B.

No salt in brine tank.

B.

Add salt to brine tank and maintain

 

 

 

 

 

salt level above water level.

 

 

C.

Injectors or screen is plugged.

C.

Replace injectors and screen.

 

 

D.

Insufficient water flowing into brine tank.

D.

Check brine tank fill time and clean

 

 

 

 

 

brine line flow control if plugged.

 

 

E.

Hard water tank hardness.

E.

Repeated flushings of the hot water

 

 

 

 

 

tank is required.

 

 

F.

Leak at distributor tube.

F.

Make sure distributor tube is not

 

 

 

 

 

cracked. Check o-ring and tube pilot.

 

 

G.

Internal valve leak.

G.

Replace seals and spacers and/or

 

 

 

 

 

piston.

3.

Unit uses too much salt.

A.

Improper salt setting.

A.

Check salt usage and salt setting.

 

 

B.

Excess water in brine tank.

B. See problem number 7.

 

 

 

 

 

 

4.

Loss of water pressure.

A.

Iron build-up in line to water conditioner.

A.

Clean line to water conditioner.

 

 

B.

Iron build-up in water conditioner.

B.

Clean control and add resin cleaner to

 

 

 

 

 

resin bed. Increase frequency of

 

 

 

 

 

regeneration.

 

 

C.

Inlet of control plugged due to foreign

C.

Remove piston and clean control.

 

 

 

material loose from pipes by recent work

 

 

 

 

 

done on plumbing system.

 

 

5.

Loss of resin through drain line.

A.

Air in water system.

A.

Assure that well system has proper air

 

 

 

 

 

elimination control, check for dry

 

 

 

 

 

well condition.

6.

Iron in conditioned water.

A.

Fouled resin bed.

A.

Check backwash, brine draw and

 

 

 

 

 

brine tank fill, increase frequency of

 

 

 

 

 

regeneration, increase backwash

 

 

 

 

 

time.

7.

Excessive water in brine tank.

A.

Plugged drain line flow control.

A.

Clean flow control.

8.

Salt water in service line.

A.

Plugged injector system.

A.

Clean injector and replace screen.

 

 

B.

Timer not cycling.

B.

Replace timer.

 

 

C.

Foreign material in brine valve.

C. Clean or replace brine valve.

 

 

D.

Foreign material in brine line flow control.

D.

Clean brine line flow control.

 

 

 

 

 

 