10
IntelliFlo VS-3050 Installation and User’s Guide

Connecting IntelliFlo VS-3050 to an EasyTouch System

The IntelliFlo can be controlled by an EasyT ouch system via the RS-485 communication cable
(P/N 350122). In this configuration, EasyT ouch starts, stops and controls the speed of the IntelliFlo pump.
When the EasyT ouch does this, it rewrites the IntelliFlo memory, which can take several seconds. This
causes a delay after a command is given on the EasyT ouch control panel until the IntelliFlo physically
responds.
The IntelliFlo control panel is disabled when communicating with the EasyT ouch system. Note that
IntelliTouch will not start communicating with the IntelliFlo until the pump is assigned to a circuit. The
IntelliFlo default pump address is one which is the only address that works with EasyT ouch. See page 6 for
details about how to check the address and change if necessary . For more information, refer to the
EasyT ouch User's Guide (P/N 520584).
T o connect the IntelliFlo communication cable to EasyTouch load center:
1. CAUTION - Switch the main power off to the EasyTouch load center.
2. Unlatch the two enclosure door spring latches, and open the door .
3. Remove the two retaining screws securing the high voltage cover panel, and remove it from the
enclosure.
4. Loosen the two access screws securing the control panel.
Retaining screw
EasyTouch Load Center (front view)
Control panel
access screw
Control panel
access screw
High voltage
cover panel