Installation and Tapping – Beer Dispensers

Installation and Tapping – Beer Dispensers

Connecting the Keg Coupler

(when Supplied by Perlick)

Place one brown leather washer into black beer

 

line connector hose on hex nut side. Screw

 

connector to stainless steel beverage line on

 

faucet standard. Tighten with a wrench, but do

 

not over tighten.

Make sure lever handle on the keg coupler is in

 

the UP (untapped) position. Place one brown

 

leather washer into wing nut end of black beer

 

line connector hose and thread onto top of keg

 

coupler. Hand tighten.

Place clamp on one end of red air line. Push

 

end over air valve located inside cabinet.

 

Tighten clamp with screwdriver. Turn shut-off

 

valve to OFF (horizontal) position.

Connecting the Regulator to the CO2 Cylinder

Remove blue plug from regulator fitting. (Note: Do not remove the carbonic washer).

Screw regulator onto gas cylinder valve. Tighten with wrench until vertically straight. Be sure that shut-off valve (black lever) on regulator is in the OFF (horizontal) position.

Place a screw clamp over end of red air line and push onto regulator tailpiece. Tighten clamp with a screwdriver.

REGULATOR

HAND

FITTING

CO2

VALVE

PRESSURE

 

GAUGE

 

30

20 40

PERLICK

Connecting the Keg Coupler1050(when Supplied by Perlick)

Place clamp on the other end of red air line and

push over tailpiece on coupler. Tighten clamp

with screwdriver.

CAUTION: Do not use keg coupler as a

handle to lift keg.

Tapping a Single Valve Keg (Sankey):

PSI

Connecting the Regulator to the CO2 Cylinder0

FITTING FOR CAUTION: Do not use keg coupler as a RED AIR HOSE

60

CO2

GAS

DRUM

REGULATOR

ADJUSTING

Step 1

Single Valve Keg Coupler

Step 3

Step 2

Be sure beer faucet is in closed position.

Align keg lugs with lug openings on bottom of coupler.

Turn clockwise 14 turn. Pull handle out and down. Keg is now tapped.

Open shut-off valve on air divider located inside of the cabinet.

Important: Be sure to close this valve when untapping keg.

SHUT-OFF VALVE SCREW (BLACK LEVER IN

CLOSED POSITION)

Adjusting the CO2 Gas Flow

Turn regulator adjusting screw counterclockwise until it turns freely.

Turn hand valve counterclockwise on CO2 cylinder to the fully open position.

Turn regulator adjusting screw clockwise until desired pressure is reached (approximately

12-15 lbs.). Tighten stop nut on adjusting screw.

Open shut-off valve on bottom of regulator.