ANTI-TIP BRACKETS

ANTI-TIP BRACKETS

WARNING

Unit may tip forward if loaded racks/shelves are all pulled out at the same time. To prevent tipping and provide a stable installation, the unit must be secured in place with the anti-tip brackets provided with the unit.

A set of metal anti-tip brackets and necessary hardware is supplied with the unit. The anti-tip brackets, when properly installed, should secure the rear legs and prevent the unit from tipping forward.

Some installation sites may require modification to provide a secure surface for attaching brackets. Refer to Figure 3 (below) for mounting bracket locations for 15” Signature Series models.

IMPORTANT NOTE: If installing on a concrete floor, concrete fasteners are required and are not included in the Anti-Tip Kit.

Figure 3 - 15” Anti-Tip Kit Drawing

Operation & Installation Manual

Signature Series (HP15 model)

WARNING

Shut off power to the wall outlet before installing unit into the opening.

2.Check that the following are level and square:

front face and interior opening

installation opening and floor surface

countertop bottom front edge

IMPORTANT NOTE: The floor under the unit must be at the same level as the surrounding finished floor.

3.If all surfaces are level, refer to Figure 4 (below) and perform the following:

a.Measure from the floor to the bottom of the front edge of the countertop.

b.Mesure the rear of the unit cabinet from floor to top of cabinet, at back corners.

c.Adjust rear legs so B measurement equals A measurement. Using an adjustable wrench or pliers, turn legs counter- clockwise to raise the unit or clockwise to lower the unit.

IMPORTANT NOTE: Leveling legs should not extend more than 3/4” from bottom of the unit.

4.Slide cabinet into position. Make sure the rear levelling legs slide under the anti-tip brackets. Push the unit into the open-

ing until the bottom front edge of the unit is flush with the surrounding cabinetry, or until the rear legs are tight against the anti-tip brackets.

Figure 4 - Leveling

INSTALLATION

CAUTION

Finished flooring should be protected with the appropriate material to avoid damage from moving the unit.

If unit has been laid on its back or sides, place unit upright and allow minimum of 24 hours before connecting power.

1.Plug in the unit into the 15 amp grounded outlet located in the installation opening. With power applied to the unit, check that the lighting and cooling function operate properly, then turn off power to the wall outlet at the circuit breaker.

7

Page 7
Image 7