C. Chase Top

A metal chase top is required to seal the top of the chase around the chimney pipe. The top should include a turn- down and drip edge to prevent water from seeping into the chase. Provide a 1/8 in. (3 mm) gap around the flue pipe and slope the top downward away from the penetration. See Figure 28.1.

All seams must be caulked to prevent leaks.

A chase installation must use a chase top. Chase tops are available from your Heat & Glo dealer or may be field constructed.

Attach the chase top to the top of the chase.

Termination Cap

2 in. (51 mm) Collar on Chase Top

Caulk

Storm Collar

Slope Downward

Turn-down

Drip Edge

Chase (Chimney)

.018 (26 ga) min. Galvanized Chase Top

Figure 28.1 Chase Top Construction

Chase Top Framing

Framing to top of chase must be constructed to support service persons, snow load, etc. Maintain 2 in. (51 mm) clearance to combustibles. Top of framing should be sheeted with plywood particle board. See Figure 28.2.

Exterior sheeting

Chase top framing

Figure 28.2

WARNING

Fire Risk

Never install a single wall slip section or smoke-pipe in a chase structure.

The higher temperature of this single wall pipe may radiate sufficient heat to combus- tible chase materials to cause a fire.

D. Install the Termination Cap

Note: To protect against the effect of corrosion on those parts exposed to the weather, the termination cap can be painted with a rust-resistant paint.

WARNING

Fire Risk

The minimum overlap of cap to pipe

MUST be met or chimney may separate from cap.

Separation allows sparks, heat and embers to escape.

Install the chimney sections up through the chase enclosure. When using a round termination cap, the uppermost top section of pipe must extend 6 in. (152 mm) above the top of the flashing collar to allow installation of the storm collar and termination cap. See Figure 28.3.

Minimum 1-1/2 in. (38 mm) overlap of cap over pipe

Storm Collar

2 in. (51 mm) min.

6 in. (152mm) min.

Flashing Collar

 

 

 

2 in. (51

mm) min. collar

 

 

Figure 28.3 Installing a TR344 Round Termination Cap

For installations utilizing a round telescoping termination cap, the uppermost chimney section must be below the top of the chase top, but not more than 14‑1/2 in. (368 mm) below the top of the chase top. Minimum overlap of chimney and termination cap must be 1-1/2 in. (38 mm).

See Figure 29.1 on page 29.

Page 28

Heat & Glo • NorthStar EPA Fireplace • 480-1081C

September 1, 2008

Page 28
Image 28
Hearth and Home Technologies NorthStar-NT, NorthStar-GT, NorthStar-BK Install the Termination Cap, Chase Top Framing

NorthStar-GT, NorthStar-BK, NorthStar-NT specifications

Hearth and Home Technologies has established itself as a leader in the production of innovative heating appliances, particularly with the launch of its NorthStar series: NorthStar-NT, NorthStar-BK, and NorthStar-GT. These models are designed to deliver superior performance, aesthetic appeal, and advanced technology, making them an excellent choice for modern homes.

The NorthStar-NT model is ideally suited for those seeking a reliable and efficient heating solution. It boasts a powerful, advanced heating technology that maximizes heat output while minimizing fuel consumption. The NorthStar-NT employs a unique combustion system that ensures a cleaner burn, resulting in fewer emissions and a lower environmental impact. The sleek design of the NorthStar-NT allows it to blend seamlessly into any room, making it not just a heating unit but also an attractive focal point.

On the other hand, the NorthStar-BK variant stands out for its versatility and aesthetic flexibility. It offers an array of customizable options, enabling homeowners to match the unit's appearance with their interior decor. The NorthStar-BK features a large viewing area, which enhances the visual appeal of the flames while providing efficient heat distribution. This model incorporates user-friendly controls that allow for easy temperature adjustments, ensuring that comfort is just a button away.

The NorthStar-GT model elevates the heating experience with its advanced smart technology features. Equipped with Wi-Fi connectivity, the NorthStar-GT allows users to control the appliance remotely via a smartphone app. This model also supports voice-activated commands, integrating seamlessly with smart home systems. The NorthStar-GT emphasizes energy efficiency, with programmable settings that enable users to optimize heating schedules to their lifestyle, ultimately contributing to energy savings.

All three NorthStar models feature durable construction and high-quality materials designed to withstand years of use. Their construction ensures not only longevity but also safety, with multiple safety features integrated into each model. Easy maintenance and cleaning options further enhance their user-friendly design.

In summary, the Hearth and Home Technologies NorthStar series including the NorthStar-NT, NorthStar-BK, and NorthStar-GT brings together cutting-edge technology, unparalleled efficiency, and stunning aesthetics. Each model caters to different needs, ensuring that homeowners can find the perfect heating solution that fits their style and requirements.