Page 16 Heat & Glo • NorthStar EPA Fireplace • 480-1081C September 1, 2008 September 1, 2008
September 1, 2008
Risk of Smoke Spillage
Outsideair inlet must be located to prevent blockage
from:
Leaves
• Snow/ice
• Otherdebris
Blockage may cause combustion air starvation.
CAUTION
Fire Risk
Asphyxiation Risk
Donotdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity.
Enclosed space such as an attic or
garage.
Clo se proximi ty to e xhaust ve nts or
chimneys.
Fumes or odor may result.
WARNING
Figure 16.1 Outside Air Inlet Locations
Attic insulation shield
must be used to keep
insulation away from
chimney.
Ceiling firestop
on floor of attic.
3 ft. (91cm) min. from top of
uppermost chimney
section to air inlet.
Handle Left - Closed
Handle Right - Open
Figure 16.2 Locating the Outside Air Control