E. Construct the Chase

A chase is a vertical boxlike structure built to enclose the fire- place and/or its vent system. Vertical chimneys that run on the outside of a building must be installed inside a chase.

In cold climates, it is recommended that the chase insulated using batt type insulation between the joists.

Construction of the chase may vary with the type of build- ing. These instructions are not substitutes for the require- ments of local building codes. Local building codes MUST be checked.

Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems. The chase should not break the outside building envelope in any manner. All outer walls need to be insulated.

Building codes require false ceiling and ceiling firestops at each floor of the chase or every 10 ft (3048 mm) of clear space to control spread of fire.

Walls, ceiling, base plate and cantilever floor at the first level of the chase should be insulated. See Figure 14.1. Vapor and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, Hearth & Home Technologies recommends that the inside surfaces be sheet rocked and taped (or the use of an equiv- alent method) for maximum air tightness.

Holes and other openings should be caulked with high tem- perature caulk or stuffed with unfaced fiber glass insulation.

WARNING

Fire Risk

DO NOT pack insulation or other combustibles: between ceiling firestops; between chimney and attic insulation shield.

ALWAYS maintain specified clearances around chimney and ceiling firestop systems.

Install ceiling firestops as specified.

Failure to keep insulation or other material away from chimney pipe may cause fire.

Materials

a.The chase is constructed using framing materials much the same as the walls in your home. A variety of siding materials may be used including brick, stone, veneer brick, or standard siding materials.

b.In constructing the chase, several factors must be considered:

1)Maintain a 2 in. (51 mm) air space around the chimney.

2)The chase top must be constructed of non-com- bustible material.

3)In cold climates, a firestop spacer should be installed in an insulated false ceiling at the 8 ft.

(2438 mm) level above the fireplace assembly. This reduces heat loss through the chase.

4)In cold climates, the walls of the chase should be insulated to the level of the false ceiling as shown in Figure 14.1. This will help reduce heat loss from the home around the fireplace.

Round Termination Cap

 

 

Storm Collar

 

Metal Chase Top

 

 

Ceiling

 

 

Firestop

 

 

False Ceiling

 

 

Attic

 

Tabs

Insulation

 

Shield

 

 

 

 

Ceiling

Insulation in the

 

outside walls

 

Firestop

 

of the chase

 

 

Insulation

Insulation

 

False Ceiling

False Ceiling

 

 

Chimney

 

Figure 14.1 Chase Assembly

 

Three examples of chase applications are shown in Fig- ure 14.2.

1.Fireplace and chimney enclosed in an exterior chase.

2.Chimney offset through exterior wall and enclosed in chase.

3.Chase constructed on roof.

All outside walls should be insulated.

1

2

3

Figure 14.2 Chase Constructions

Page 14

Heat & Glo • NorthStar EPA Fireplace • 480-1081C

September 1, 2008

Page 14
Image 14
Hearth and Home Technologies NorthStar-BK, NorthStar-GT, NorthStar-NT owner manual Construct the Chase, Materials

NorthStar-GT, NorthStar-BK, NorthStar-NT specifications

Hearth and Home Technologies has established itself as a leader in the production of innovative heating appliances, particularly with the launch of its NorthStar series: NorthStar-NT, NorthStar-BK, and NorthStar-GT. These models are designed to deliver superior performance, aesthetic appeal, and advanced technology, making them an excellent choice for modern homes.

The NorthStar-NT model is ideally suited for those seeking a reliable and efficient heating solution. It boasts a powerful, advanced heating technology that maximizes heat output while minimizing fuel consumption. The NorthStar-NT employs a unique combustion system that ensures a cleaner burn, resulting in fewer emissions and a lower environmental impact. The sleek design of the NorthStar-NT allows it to blend seamlessly into any room, making it not just a heating unit but also an attractive focal point.

On the other hand, the NorthStar-BK variant stands out for its versatility and aesthetic flexibility. It offers an array of customizable options, enabling homeowners to match the unit's appearance with their interior decor. The NorthStar-BK features a large viewing area, which enhances the visual appeal of the flames while providing efficient heat distribution. This model incorporates user-friendly controls that allow for easy temperature adjustments, ensuring that comfort is just a button away.

The NorthStar-GT model elevates the heating experience with its advanced smart technology features. Equipped with Wi-Fi connectivity, the NorthStar-GT allows users to control the appliance remotely via a smartphone app. This model also supports voice-activated commands, integrating seamlessly with smart home systems. The NorthStar-GT emphasizes energy efficiency, with programmable settings that enable users to optimize heating schedules to their lifestyle, ultimately contributing to energy savings.

All three NorthStar models feature durable construction and high-quality materials designed to withstand years of use. Their construction ensures not only longevity but also safety, with multiple safety features integrated into each model. Easy maintenance and cleaning options further enhance their user-friendly design.

In summary, the Hearth and Home Technologies NorthStar series including the NorthStar-NT, NorthStar-BK, and NorthStar-GT brings together cutting-edge technology, unparalleled efficiency, and stunning aesthetics. Each model caters to different needs, ensuring that homeowners can find the perfect heating solution that fits their style and requirements.