Installation and commissioning

8.01.06 Mounting the spool holder

● Mount the spool holder as shown in Fig. 8-08.

● Insert the spool holder into the hole in the table top and fasten it with the nuts enclosed.

Fig. 8 - 06

8.02 Connecting the plug-in connections and earth cables

1

Fig. 8 - 07

Connect all plug connections as described in the operations manual of the drive

The following ground cables must be attached in order to discharge static electricity.

Attach ground cables for machine, main switch, control unit and motor to ground point 1.

21