HID-DynaVision SON and CDO
|
| A2 |
B1 | B2 | D1 |
|
| |
|
| A3 |
| C1 |
|
|
| A1 |
Type | A1Nom | A2Nom | A3Nom | B1Nom | B2Nom | C1Nom | D1Nom |
|
|
|
|
|
|
|
|
150.0 | 134.0 | 136.0 | 90.0 | 70.0 | 40.0 | 4.5 | |
|
|
|
|
|
|
|
|
HID Gear
Inrush current
Type |
| Maximum | Inrush | Inrush |
|
| gear number | current | current |
|
| on MCB | Peak | Width |
|
| (x) | (A) | (ms) |
|
|
|
|
|
100/150 SON/CDO | 8 | 50 | 0.5 | |
|
|
|
|
|
70 SON/CDO | 12 | 35 | 0.5 | |
|
|
|
|
|
Electrical data
Type |
|
| Number | Rated | Line | Line | Ignition | ||||
|
|
| of | Gear- | Frequency | Voltage | life | maximum |
| Voltage | outputwires |
|
|
| Lamps | Lamp |
|
|
|
|
|
| mutual |
|
|
| (x) | Power | (Hz) | (V) | (ºC) | (ºC) |
| (kV) | (pF) |
|
|
|
|
|
|
|
|
|
| ||
1 | 100 | 50/60 | 90 | 100 | 50 | 4.00 | 200 | ||||
|
|
|
|
|
|
|
|
|
|
| |
/S SON | 1 | 100 | 50/60 | 90 | 100 | 50 | 4.00 | 1000 | |||
|
|
|
|
|
|
|
|
|
|
| |
/S CDO | 1 | 150 | 50/60 | 90 | 100 | 45 | 4.00 | 200 | |||
|
|
|
|
|
|
|
|
|
|
|
|
150 | /S SON | 1 | 150 | 50/60 | 90 | 100 | 45 | 4.00 | 1000 | ||
|
|
|
|
|
|
|
|
|
|
| |
70 /S CDO | 1 | 70 | 50/60 | 90 | 100 | 50 | 2.50 | 200 | |||
|
|
|
|
|
|
|
|
|
|
| |
70 /S SON | 1 | 70 | 50/60 | 90 | 100 | 50 | 2.50 | 1000 | |||
|
|
|
|
|
|
|
|
|
|
|
|
Ordering and packing data
Type |
|
|
| Weight | Qty bulk | Dimensions bulk packing | EAN code | EOC |
|
|
|
|
| packing |
| bulk packing | 8711500 |
|
|
|
|
|
| |||
0.725 kg | 10 | 39.8 cm x 16 cm x 11.1 cm | 8711500931337 | 931320 30 | ||||
|
|
|
|
|
|
| ||
/S SON | 0.725 kg | 10 | 39.8 cm x 16 cm x 11.1 cm | 8711500749062 | 749055 30 | |||
|
|
|
|
|
|
| ||
/S CDO | 0.725 kg | 10 | 39.8 cm x 16 cm x 11.1 cm | 8711500538109 | 538093 30 | |||
|
|
|
|
|
|
|
| |
150 | /S SON | 0.725 kg | 10 | 39.8 cm x 16 cm x 11.1 cm | 8711500538086 | 538079 30 | ||
|
|
|
|
|
|
|
| |
70 | /S CDO | 0.725 kg | 10 | 39.8 cm x 16 cm x 11.1 cm | 8711500931351 | 931344 30 | ||
|
|
|
|
|
|
|
| |
70 | /S SON | 0.725 kg | 10 | 39.8 cm x 16 cm x 11.1 cm | 8711500927330 | 927323 30 | ||
|
|
|
|
|
|
|
|
|
Electrical installation notes |
|
Mains operation |
|
Rated mains voltage | 220 - 240 V |
With tolerances for performance | 203 - 254 V |
| |
With tolerances for operation | 180 - 264 V |
Mains frequency | 50/60 Hz |
Power factor 100% power | > 0.98 |
Power factor 35%, SON, 60%, | > 0.93 |
CDO, power |
|
Earth leakage current | < 0,5 mA per driver |
Overvoltage protection | 48 hrs at 325 Vac |
| 2 hrs at 366 Vac |
| 5 min. at 400 Vac |
Lamp operation |
|
Operation frequency (typical) | 125 Hz |
Ignition voltage | 3 - 4 kV |
Cable capacity |
|
SON | Max. 1 nF |
CDO | Max. 200 pF |
Air and creepage distance from any | > 4 mm |
(metal) part that may become live, |
|
to earthed environment (class I) or |
|
test finger (class II) |
|
OEM Catalogue 2009/2010 | 3.109 |