HID-DynaVision SON and CDO

 

 

A2

B1

B2

D1

 

 

 

 

A3

 

C1

 

 

 

A1

HID-DV

Type

A1Nom

A2Nom

A3Nom

B1Nom

B2Nom

C1Nom

D1Nom

 

 

 

 

 

 

 

 

HID-DynaVision 1-10V SON/CDO

150.0

134.0

136.0

90.0

70.0

40.0

4.5

 

 

 

 

 

 

 

 

HID Gear

Inrush current

Type

 

Maximum

Inrush

Inrush

 

 

gear number

current

current

 

 

on MCB

Peak

Width

 

 

(x)

(A)

(ms)

 

 

 

 

 

HID-D 1-10V

100/150 SON/CDO

8

50

0.5

 

 

 

 

 

HID-D 1-10V

70 SON/CDO

12

35

0.5

 

 

 

 

 

Electrical data

Type

 

 

Number

Rated

Line

Line

T-case

T-case

T-ambient

Ignition

Cable-Cap

 

 

 

of

Gear-

Frequency

Voltage

life

maximum

 

Voltage

outputwires

 

 

 

Lamps

Lamp

 

 

 

 

 

 

mutual

 

 

 

(x)

Power

(Hz)

(V)

(ºC)

(ºC)

 

(kV)

(pF)

 

 

 

 

 

 

 

 

 

 

HID-D 1-10V 100 /S CDO 220-240V

1

100

50/60

220-240

90

100

50

4.00

200

 

 

 

 

 

 

 

 

 

 

 

HID-D 1-10V 100

/S SON 220-240V

1

100

50/60

220-240

90

100

50

4.00

1000

 

 

 

 

 

 

 

 

 

 

 

HID-D 1-10V 150

/S CDO 220-240V

1

150

50/60

220-240

90

100

45

4.00

200

 

 

 

 

 

 

 

 

 

 

 

 

HID-D 1-10V

150

/S SON 220-240V

1

150

50/60

220-240

90

100

45

4.00

1000

 

 

 

 

 

 

 

 

 

 

 

HID-D 1-10V

70 /S CDO 220-240V

1

70

50/60

220-240

90

100

50

2.50

200

 

 

 

 

 

 

 

 

 

 

 

HID-D 1-10V

70 /S SON 220-240V

1

70

50/60

220-240

90

100

50

2.50

1000

 

 

 

 

 

 

 

 

 

 

 

 

Ordering and packing data

Type

 

 

 

Weight

Qty bulk

Dimensions bulk packing

EAN code

EOC

 

 

 

 

 

packing

 

bulk packing

8711500

 

 

 

 

 

 

HID-D 1-10V 100 /S CDO 220-240V 50/60Hz

0.725 kg

10

39.8 cm x 16 cm x 11.1 cm

8711500931337

931320 30

 

 

 

 

 

 

 

HID-D 1-10V 100

/S SON 220-240V 50/60Hz

0.725 kg

10

39.8 cm x 16 cm x 11.1 cm

8711500749062

749055 30

 

 

 

 

 

 

 

HID-D 1-10V 150

/S CDO 220-240V 50/60Hz

0.725 kg

10

39.8 cm x 16 cm x 11.1 cm

8711500538109

538093 30

 

 

 

 

 

 

 

 

HID-D 1-10V

150

/S SON 220-240V 50/60Hz

0.725 kg

10

39.8 cm x 16 cm x 11.1 cm

8711500538086

538079 30

 

 

 

 

 

 

 

 

HID-D 1-10V

70

/S CDO 220-240V 50/60Hz

0.725 kg

10

39.8 cm x 16 cm x 11.1 cm

8711500931351

931344 30

 

 

 

 

 

 

 

 

HID-D 1-10V

70

/S SON 220-240V 50/60Hz

0.725 kg

10

39.8 cm x 16 cm x 11.1 cm

8711500927330

927323 30

 

 

 

 

 

 

 

 

 

Electrical installation notes

 

Mains operation

 

Rated mains voltage

220 - 240 V

With tolerances for performance

203 - 254 V

+6%-8%

 

With tolerances for operation

180 - 264 V

Mains frequency

50/60 Hz

Power factor 100% power

> 0.98

Power factor 35%, SON, 60%,

> 0.93

CDO, power

 

Earth leakage current

< 0,5 mA per driver

Overvoltage protection

48 hrs at 325 Vac

 

2 hrs at 366 Vac

 

5 min. at 400 Vac

Lamp operation

 

Operation frequency (typical)

125 Hz

Ignition voltage

3 - 4 kV

Cable capacity

 

SON

Max. 1 nF

CDO

Max. 200 pF

Air and creepage distance from any

> 4 mm

(metal) part that may become live,

 

to earthed environment (class I) or

 

test finger (class II)

 

OEM Catalogue 2009/2010

3.109

Page 109
Image 109
Philips 220-230-240V, 380-400-415V manual Mains operation Rated mains voltage 220 240