HID-EXC for SOX lamps

A2

D1

B1

C1

A1

EXC

 

 

 

 

 

 

 

 

Type

A1Nom

A2Nom

B1Nom

C1Nom

D1Nom

 

 

 

 

 

 

 

 

 

EXC 35/36/55/66 SOX(-E)

280.0

265.0

39.0

28.0

4.2

 

 

EXC 91 SOX-E

335.0

325.0

39.0

28.0

4.2

HID Gear

 

 

 

 

 

 

 

 

 

 

 

 

Inrush current

Type

Inrush

Inrush

 

current

current

 

Peak

Width

 

(A)

(ms)

 

 

 

EXC 35/36 SOX(-E)

30

0.15

 

 

 

EXC 55/66 SOX(-E)

40

0.15

 

 

 

EXC 91 SOX-E

50

0.22

 

 

 

Electrical data

Type

 

Number

Rated

Power

Line

Line

T-case

T-case

T-ambient

Cable-Cap

 

 

of

Gear-

losses

Frequency

Voltage

life

maximum

 

outputwires

 

 

Lamps

Lamp

gear

 

 

 

 

 

mutual

 

 

(x)

Power

(W)

(Hz)

(V)

(ºC)

(ºC)

 

(nF)

 

 

 

 

 

 

 

 

 

 

EXC 35 SOX 220-240V 50/60Hz

1

35

4

50/60

220-240

65

65

50

1

 

 

 

 

 

 

 

 

 

 

EXC 36 SOX-E 220-240V 50/60Hz

1

36

4

50/60

220-240

65

65

50

0.5

 

 

 

 

 

 

 

 

 

 

 

EXC 55

SOX 220-240V 50/60Hz

1

55

4

50/60

220-240

65

65

50

2

 

 

 

 

 

 

 

 

 

 

 

EXC 66

SOX-E 220-240V 50/60Hz

1

66

5

50/60

220-240

65

65

50

2

 

 

 

 

 

 

 

 

 

 

 

EXC 91

SOX-E 220-240V 50/60Hz

1

91

7

50/60

220-240

65

65

50

1

 

 

 

 

 

 

 

 

 

 

 

Ordering and packing data

Type

 

 

Weight

Qty bulk

Dimensions bulk packing

EAN code

EOC

 

 

 

 

packing

 

bulk packing

8711500

 

 

 

 

 

 

EXC 35 SOX 220-240V 50/60Hz

0.266 kg

25

31.3 cm x 22.5 cm x 21.4 cm

8711500062390

062383 30

 

 

 

 

 

 

 

EXC 36 SOX-E 220-240V

50/60Hz

0.267 kg

25

31.3 cm x 22.5 cm x 21.4 cm

8711500062413

062406 30

 

 

 

 

 

 

 

EXC 55

SOX 220-240V 50/60Hz

0.289 kg

25

31.3 cm x 22.5 cm x 21.4 cm

8711500062437

062420 30

 

 

 

 

 

 

 

 

EXC 66

SOX-E 220-240V

50/60Hz

0.289 kg

25

31.3 cm x 22.5 cm x 21.4 cm

8711500062451

062444 30

 

 

 

 

 

 

 

 

EXC 91

SOX-E 220-240V

50/60Hz

0.333 kg

10

37.6 cm x 20.6 cm x 7.6 cm

8711500741097

741080 30

 

 

 

 

 

 

 

 

Electrical installation notes

Note:

In order to reset stop circuit of electronic driver, mains supply must be switched off for ten seconds when replacing defective lamp.

EXC

OEM Catalogue 2009/2010

3.117

Page 117
Image 117
Philips 220-230-240V, 380-400-415V manual Type A1Nom A2Nom B1Nom C1Nom D1Nom