Filter replacement

The lifetime of the filters is substantially shortened by exposure to tabacco smoke:

number of cigarettes per day

estimated lifetime of filters

0

- 1

up to 5 years

5

- 10

up to 6 to 12 months

20

up to 3 - 6 months

ESP particle filter

,In case of normal household use in a non-smoking environment and in case of proper maintenance (see chapter ‘Cleaning and maintenance’), the particle filter lasts approx. 5 years.

,To check if you have to replace the ESP particle filter you have to remove the front cover and pull out the ESP particle filter with two hands (Fig. 4).

,Turn the ESP particle filter upside down (Fig. 16).

,Check the pollution between the layers and judge which pollution level applies. Only replace filter in case pollution bridges two layers. (Fig. 17)

,A new ESP particle filter is available under the following type numbers:

-AC4107 for CleanAir System AC4055/AC4053

-AC4108 for CleanAir System AC4065/AC4063

Zeolite gas filter

In case of normal household use in a non-smoking environment and in case of proper maintenance

(see chapter ‘Cleaning and maintenance’), the zeolite gas filter lasts up to 5 years.

Note:You may need to replace the zeolite gas filter sooner in case of more extreme usage conditions (smoking environment, just renovated room, non-domestic use etc.) and insufficient maintenance.

,Replace the zeolite gas filter when you have to replace the ESP particle filter.

,A new zeolite gas filter is available under the following type numbers:

-AC4117 for CleanAir System AC4055/AC4053

-AC4118 for CleanAir System AC4055/AC4053

Removing the filters

Tip: Place the appliance against a wall for more stability when you remove or insert filters.

1Place your fingers in the recesses of the side panels. Gently pull the top part of the front panel off the appliance (1) and then lift the panel upwards to remove it (2) (Fig. 3).

2To remove the ESP particle filter, grab the filter handles at both sides and gently slide the filter out of the appliance. (Fig. 4)

3To remove the zeolite gas filter, slide it out of the appliance (Fig. 18).

Note:You can only remove the zeolite gas filter after you have removed the ESP particle filter.

4To remove the pre-filter, slide it out of the appliance (Fig. 19).

Inserting the filters

Tip: Place the appliance against a wall for more stability when you remove or insert filters.

Note: Make sure you insert the filters in the correct position (with the arrow facing upwards).

Note:The appliance is equipped with a safety device. If you have not placed the ESP particle filter, the zeolite gas filter and the front panel properly, you cannot switch on the appliance.

1 Slide the zeolite gas filter into the appliance. (Fig. 5)