Contact Strips (Models 340, 34H, 350, 355, 360/36T, 365, 370/37T, 375)
Removal
1..Set the power switches of the system unit to Off.
2..Do the removal procedure in ªRear Coverº on page
3..Do the removal procedure in ªTop Coverº on page
4..Peel off the contact strip from the bottom side of the top cover, if this is the one to be replaced. Go to the replacement procedure following.
5..Do the removal procedure in ªPower Supplyº on page
6..Peel off the contact strip from the right side of the base.
Replacement
1..Clean off any tape remaining from the old contact strip.
2..Remove the release paper from the new contact strip.
3..Press the contact strip to the cover in the location shown. The adhesive requires 24 hours to reach full strength. Use extra care during reassembly.
4..Replace parts in reverse order.
Power
Supply Area
Location
Top Cover Area Location 340 and 350 only