Step 1

(from Steps 3, 7, 8, 9, and 14)

1.Ensure that the diagnostics and the operating system are shut down.

2.Turn the key mode switch to the Service position.

3.Set the power switch on the system unit to Off.

4.Insert the first diagnostic diskette into the diskette drive.

5.Set the power switch on the system unit to On.

6.Find the symptom in the following table that best matches the symptom on your system, and then perform the associated task.

Information in

 

 

three-digit dis-

Other conditions

Do this:

play

 

 

 

 

 

Nothing

Diagnostic Operating Screen is displayed

Go to Step 14.

 

 

 

c07

The diskette drive ªIn-Useº light is on

Insert the next diagnostic

 

 

diskette.

 

 

Wait for one of the other

 

 

symptoms in this table to

 

 

occur.

 

 

 

888 flashing

 

Go to Step 2.

 

 

 

Two or more num-

First diagnostic diskette is loaded

Go to Step 7.

bers between 221

 

 

and 296 are dis-

 

 

played alternately.

 

 

 

 

 

c31

Instructions to select the system console

Follow the instructions on

 

displayed on the screen.

the screen. Wait for one of

 

 

the other symptoms in this

 

 

table to occur.

 

 

 

c05

The diskette drive ªIn-Useº light is on

The diagnostic diskette is

 

 

probably bad. Insert the

 

 

same diskette from a du-

 

 

plicate diagnostic set. If

 

 

the duplicate diskette

 

 

causes the same symp-

 

 

tom, Go to Step 7.

 

 

 

299 or less

Digits on solid for more than 3 minutes,

Go to Step 2.

 

and the power light is on.

 

 

 

 

300 or greater

Digits on solid for more than 3 minutes,

Go to Step 7.

 

and the power light is on.

 

 

 

 

570

Digits on solid for more than 3 minutes,

Down level SCSI-2 code.

 

and the power light is on.

Run diagnostics with re-

 

 

movable media.

 

 

 

Any symptom not listed above.

Go to Step 2.

 

 

 

2-1540-2Installation and Service Guide

Page 44
Image 44
IBM 7012 manual Information Three-digit dis Other conditions Do this