Step 8
(from Step 7)
1.Set the power switch on the system unit to Off.
2.Install and connect the disk drive frame and disk drives.
3.For Models 320, 32E, and 32H with
4.For Models 320, 32E, and 32H with
For Models 320, 32E, and 32H with
5.Insert the first diagnostic diskette into the diskette drive.
6.Set the power switch on the system unit to On.
7.Wait for one of the following conditions to occur:
•The
•The system stops for at least three minutes and a constant number, character, or symbol is displayed in the
•The system stops and two or more numbers with values between 221 and 296 are displayed alternately in the
•The system stops and a flashing 888 is displayed in the
•The power light does not come on, or the power light comes on but does not stay on.
Is the
NO | One of the FRUs remaining in the system unit is defective. | |
| In the following order, exchange the FRUs that have not been exchanged: | |
| • For Models 320, 32E, and 32H with | |
| drives: | |
| 1. | Rear disk drive (if |
| 2. | Front disk drive (if |
| 3. | Riser card (if present) |
| 4. | SCSI adapter (if present) |
|
| Note: Refer to POWERstation and POWERserver Common |
|
| Diagnostics and Service Guide, ª |
|
| Blowingº. |
| 5. | SCSI cable (if present) |
| 6. | SCSI terminator |
| 7. | System planar |
| 8. | Power supply. |
Maintenance Analysis Procedures