TROUBLESHOOTING

 

 

 

 

 

 

Problem

Explanation / Resolution

 

 

 

 

 

 

 

 

Ensure that a null modem serial cable is connected between the IntuiKey keyboards and the serial

 

 

 

 

hub.

 

 

 

Ensure that the appropriate communications port is properly configured for the serial hub.

 

Keyboards are not communicating with the ADIM

Ensure that the serial hub is connected to the network switch with a straight-through Ethernet cable.

 

Ensure that the ADIM software computer is connected to the network switch with a straight-through

 

Software

 

Ethernet cable.

 

 

 

NOTE: If the COM port light is green (OK), this confirms the ADIM software successfully opened the

 

 

 

COM port. (The COM port exists and is not in use by another application.)

 

 

 

 

 

Pressing ADIM Controls on the IntuiKey

 

 

 

results in the Allegiant monitor displaying the output

Set the Hi-Q Recorder’s password to 1234.

 

of the Hi-Q’s MON A in Live mode instead of

 

 

 

 

Playback mode. (No error messages are displayed

 

 

 

on the Allegiant monitor.)

 

 

 

 

 

 

 

 

 

 

Ensure that the ADIM software is up and running in normal operations mode.

 

 

 

Verify that the RS-232 cable from the keyboard to the serial hub is connected properly.

 

Keyboards display ADIM Off-line

The keyboard may go off-line and lose communication with ADIM if excessive conducted power

 

 

disturbance is present on the system’s serial and/or ethernet interfaces. To re-establish communication,

 

 

 

 

 

 

 

 

first identify and remove the source of the disturbance, or protect the system’s serial and/or ethernet

 

 

 

 

interfaces from the disturbance, and then close and restart the ADIM PC software.

 

 

 

Verify that the serial hub and ADIM PC is on the same network segment.

 

 

 

 

 

Error Message 100

The ADIM system has found the DVR associated with the keyboard user’s request, but another user is

 

DVR in Use is displayed on the IntuiKey keyboard

 

presently using the DVR.

 

when DVR Control is pressed on the IntuiKey

 

Wait for the DVR to be released by the other user.

 

keyboard

 

 

 

 

 

 

 

 

 

 

The user has requested playback from a device (either a camera or monitor) that could not be found in

 

 

 

the ADIM mapping tables.

 

Error Message 101

Ensure that the ADIM mapping tables are correct.

 

Requested Devices Not Found is displayed on the

Ensure that the DVR associated with the requested device is on-line.

 

IntuiKey keyboard

Ensure that in the case of a camera not being found that the associated DVR is marked as a playback

 

 

 

 

or backup DVR.

 

 

 

Ensure that in the case of a monitor not being found, the associated DVR is marked as a review DVR.

 

 

 

 

 

 

 

Communications have failed between the ADIM PC software and the IntuiKey keyboards.

 

 

 

Verify that the ADIM software is still running.

 

 

 

Examine the Log file in the ADIM software to determine the reason for the communications failure.

 

Error Message 102

Ensure that the keyboard is connected to the serial hub using a 9-pin null modem cable.

 

ADIM Communication Error is displayed on the

Ensure that the serial hub is turned on and functioning properly (consult the manual that came with

 

IntuiKey keyboard

 

serial hub).

 

 

 

Ensure that the keyboard is connected to the same serial port as defined in the ADIM software.

 

 

 

Ensure that the ADIM system has associated a valid serial port to the keyboard.

 

 

 

Ensure that the ADIM software and PC is running properly.

 

 

 

 

 

Error Message 103

The ADIM software wishes to gain attention of the user due to detection of an error.

 

ADIM General Error is displayed on the IntuiKey

 

Consult the ADIM software PC and associated log file.

 

keyboard

 

 

 

 

 

 

 

 

Error Message 104

The IntuiKey keyboard and ADIM software are not synchronized.

 

ADIM Mode Conflict Error is displayed on the

 

No action is required; the keyboard and ADIM software will automatically synchronize.

 

IntuiKey keyboard

 

 

 

 

 

 

 

 

 

18