Diagnostic Software, Trouble Shooting and Test Instructions

DVD763SA

 

5.

 

EN 29

After one loop cycle: Display the 3-digit module bits together with the last error code which occured in the loop test. The 4 digits at the right side of the display (fig. 5-34) show the last error that was found during the loop test. The leftmost two digits

(54) of this code indicates which nucleus resulted in a fault. The rightmost two digits (03) refer to the faultcode within that nucleus. For further explanation of this error code, refer to chapter 5.8 (Nuclei Error Codes).

5.6.1Errorlog

Explanation:

The application errors will be logged in the NVRAM. The maximum number of error bytes that will be visible is 16. The first word (4 digits) of the byte is the component identification, the last word is the error code.

The diagnostics software will present a combination of this component identification plus an error code on the local display (and on the attached terminal). The last reported error is shown as < 00000000, the oldest visible error as 00000000 > and the errors in between as < 00000000 >.

The devices that may report errors are the serial controller (UART), the basic engine (BE), the slave processor (SLPH), the SACD Stream Manager (SSM) and the SACD Media Access (SMA). The identification of these components is as follows:

Component name

Component identification

Serial controller (UART)

000A

 

 

Engine (BE)

0016

 

 

Slave Processor (SLPH)

001A

 

 

SACD Stream Manager

001C

(SSM)

 

 

 

SACD Media Access (SMA)

002E

 

 

Diagnostic software (DS)

Dxxx

 

 

The tables in the next chapters list the error code and corresponding problem. The column ‘Explanation’ holds a more elaborate description and the most likely reason for the error.

Some Examples:

002E0000 (SMA reported a timeout error)

0016010A (Engine could not fully close or open the tray) D0010001 (Flash checksum failed).

For further explanation of DS errors, see description of nucleui error codes in paragraph 5.8.

UART Error Codes

Error

Error

 

 

 

Number

name

 

Explanation

 

 

 

 

 

 

0000

 

BUF_OVE

 

To many characters were offered in

 

 

RFLOW

 

too little time. Reason: system was

 

 

 

 

too busy doing other jobs.

 

 

 

 

 

 

0001

 

COMMUNI

 

Usually a protocol error. Reason:

 

 

CATION

 

bad connection between engine

 

 

 

 

and processor.

 

 

 

 

 

 

0002

 

TIME OUT

 

 

 

 

 

 

 

 

 

BE Errors

 

 

 

 

 

 

 

 

 

 

Error

 

 

 

 

 

Number

 

Error name

 

Explanation

 

 

 

 

 

0101

 

S2B_ILL_CO

 

Parameter(s) not valid for this

 

 

MMAND

 

command. Reason: some

 

 

 

 

 

communication problem

 

 

 

 

 

between UART and engine.

 

 

 

 

0102

 

S2B_ILL_PAR

Command not allowed in this

 

 

AM

 

state or unknown. Reason: see

 

 

 

 

 

S2B_ILL_COMMAND error

 

 

 

 

 

 

Error

 

 

Number

Error name

Explanation

 

 

 

0103

S2B_SLEDGE

Sledge could not be moved to

 

 

home position.

 

 

 

0104

S2B_FOCUS

Focus failure

 

 

 

0105

S2B_MOTOR

Motor could not reach speed

 

 

within timeout

 

 

 

0106

S2B_RADIAL

Servo didn't get on track after

 

 

several retries.

 

 

 

0107

S2B_PLL_LO

PLL could not lock in Accessing

 

CK

or Tracking state

 

 

 

0108

SBC_HEADE

Header timeout

 

R_TO

 

 

 

 

0109

S2B_SBC_NO

Requested subcode item could

 

T_FOUND

not be found.

 

 

 

010A

S2B_TRAY

Tray could not be opened or

 

 

closed completely.

 

 

 

010B

S2B_TOC_RE

TOC could not be read within

 

AD

timeout period.

 

 

 

010C

S2B_JUMP

Requested seek could not be

 

 

performed.

 

 

 

010D

S2B_NON_EX

Attempt to access a non-existing

 

IST_SES

session.

 

 

 

010E

S2B_NON_EX

Caller tries to acces a non-

 

IST_BCA

existing BCA area

 

 

 

010F

Speed setting

A wrong or inappropraiate speed

 

 

value has been set

 

 

 

0116

NO_DISC

No disc selected

 

 

 

011A

TRAY_INIT

After reset, initialized tray

 

 

 

011B

NO TOC INFO

No TOC information in lead-in

 

 

area or erase TOC found

 

 

 

01F0

S2B_OVERR

Too many bytes received over

 

UN

S2B Reason: see

 

 

S2B_ILL_COMMAND error

 

 

 

01F1

S2B_COMM_

Not enough bytes are received

 

TO

over S2B Reason: see

 

 

S2B_ILL_COMMAND error

 

 

 

01F2

S2B_PARITY

Byte received with parity error.

 

 

Reason: see

 

 

S2B_ILL_COMMAND error

 

 

 

01F3

S2B_ILL_PHA

CMD IDC is not valid,

 

SE

transmission out of sync.

 

 

Reason: see

 

 

S2B_ILL_COMMAND error

 

 

 

01F4

S2B_ILL_NR_

Byte count has an illegal value.

 

OF_BYTES

Reason: see

 

 

S2B_ILL_COMMAND error

 

 

 

SLPH Error Codes

 

 

 

 

Error

 

 

Number

Error name

Explanation

 

 

 

0000

COMMUNICA

Error in I2C communication.

 

TION

Reason: bad connection

 

 

between slave processor and

 

 

main processor.

 

 

 

SSM Error Codes

 

 

 

 

Error

 

 

Code

Error name

Explanation

 

 

 

0006

SP_SYNCER

System cannot get synchronised

 

ROR

with sectors coming from disc.

 

 

Reason: Usually a damaged

 

 

disc or the player was dropped/

 

 

pushed during operation. If not,

 

 

the engine is malfunctioning.

 

 

 

0007

SP_EDCERR

Data coming from disc is

 

OR

damaged. Reason: see

 

 

SP_SYNCERROR

 

 

 

Page 14
Image 14
Philips DVD763SA/051 manual Explanation, Some Examples, Uart Error Codes, Be Errors, Slph Error Codes, SSM Error Codes

DVD763SA/051, DVD763SA/021, DVD763SA/001 specifications

The Philips DVD763SA series, which includes models DVD763SA/001, DVD763SA/021, and DVD763SA/051, represents a sophisticated blend of technology and quality in the realm of home entertainment. These DVD players are designed to deliver an exceptional viewing experience, featuring a range of functionalities that cater to modern media consumption needs.

One of the standout features of the DVD763SA series is its compatibility with various disc formats. It supports not just standard DVDs, but also CD-R/RW, MP3, and JPEG formats, allowing users to enjoy a versatile selection of media. This versatility ensures that whether you're in the mood for a classic movie, listening to music, or viewing photos from a digital camera, the Philips DVD763SA delivers seamless playback.

Equipped with progressive scan technology, these DVD players enhance video quality significantly. This technology minimizes motion blur and improves image clarity, producing a sharper picture that enhances the viewing experience, especially on larger screens. The DVD763SA series also boasts an advanced video rendering capability, which ensures that even older discs are upscaled to near-HD quality, providing a more enjoyable viewing experience.

Another notable characteristic of the DVD763SA series is its user-friendly interface. The remote control is ergonomically designed for ease of use, incorporating intuitive buttons that allow for quick access to settings, playback options, and media navigation. The on-screen display further simplifies navigation, making it easy for users to browse through their media collections.

Audio quality is equally impressive, with support for Dolby Digital and DTS sound formats. This ensures that viewers can enjoy cinematic audio experiences from the comfort of their homes. The players also feature direct audio outputs, enabling users to connect them to external sound systems for enhanced sound performance.

The Philips DVD763SA series prioritizes energy efficiency, adhering to environmentally friendly standards. This not only helps reduce power consumption but also contributes to lower electricity bills for households. With a sleek and compact design, these DVD players fit seamlessly into any home entertainment setup, providing both functionality and style.

In summary, the Philips DVD763SA/001, DVD763SA/021, and DVD763SA/051 models combine advanced technology with practical features, making them an excellent choice for anyone looking to upgrade their home media experience. From impressive audio-visual capabilities to user-friendly design, these players are well-equipped to meet the demands of today's media consumers.