Philips DVP3320/55 service manual No display on LED, and buttons do not work, Correct connection

Models: DVP3320 DVP3320/55

1 39
Download 39 pages 22.18 Kb
Page 18
Image 18

5-6

Trouble shooting chart

 

 

 

No display on LED, and buttons do not work

No display on LED, and buttons do not work

Yes

Check

whether

there is

No

correct

contact

between

 

XS301 and XP1

Yes

Check VCC(+5v) voltage

No

on the power and front

 

board

 

Yes

Correct connection

Fix power supply board top a power supply for should electric circuit

Check there are CS, DATA

No

and CLK signals on XS301

 

on the front board.

 

Check the U2’s pin 48,95,96 arrive the XP1 connect condition

XP1 (PIN 1 CLK)

XP1 (PIN3 DOUT)

Yes

1.Check whether bad solder exists on

 

U600 and pins of LED,

No

2.Check whether the circuit connected to

 

K301,K302,is broken,

 

3.Check whether R303,R301,R302 are

 

open-circuit.

 

Yes

Replace U301 or LED

Correct connection

Page 18
Image 18
Philips DVP3320/55 service manual No display on LED, and buttons do not work, Correct connection