5-1

Trouble shooting chart

 

Spindle motor does not move

Motor no move

Go

Check the FFC connection between 24P and the loader.

Yes

Check whether “RFA5V” (+5V) voltage is normal.

Yes

Check whether laser voltage

(2.3V for DVD & 1.9V for CD)

on Collector of Q4 and Q5

Yes

1.Whether voltage on pin 97 of U2 varies between 0 and 3.3V (3.3V for CD and 0V for DVD),

2.Whether peripheral components are eroded or badly soldered.

Yes

Have no focus

Yes

Check/Replace the loader

No

Correct connection

 

No

Check the RFA5V power

 

supply

 

 

No

Check/Replace Q4 Q5.

 

 

No

Check/ Replace U2.

1.Check U2 pin89 FOCUS_PWM

No

signals

 

 

2.If there are F+, F-, T+ and T-

 

signals output from U4.

 

 

 

 

 

 

 

FOCUS_PWN waveform

 

 

 

 