SP200/210

Maxon SP200/210 Radio

6.3 Voltage Charts

The following voltages have been measured on a VHF radio. The Control Circuit, Main Circuit and Integrated Circuit voltages apply to the UHF radio as well.

6.3.1 Transistors (Main Circuit)

 

 

 

 

 

Rx

 

 

 

Ref. No.

 

B

 

C

E

 

 

Q5

0

0

0

 

 

Q6

 

4.0

 

0.7

1.5

 

 

Q7

 

5

 

0

0

 

 

Q10

 

0.5

 

0

0

 

 

Q11

 

3.0

 

4.0

0

 

 

Q12

 

5

 

0

0

 

 

Q13

 

14

 

14

14

 

 

Q14

 

0.5

 

0

0

 

 

Q15

 

4.0

 

4.0

0

 

 

Q16

 

0

 

3.0

4.0

 

 

Q17

 

3.0

 

0

0

 

 

Q18

 

0

 

4.0

4.0

 

 

Q19

 

4.0

 

0

4.5

 

 

Q20

 

0

 

4

4

 

 

Q21

 

4.0

 

4.0

0

 

 

Q22

 

4.5

 

0

0

 

 

Q23

 

4.0

 

0.7

4.5

 

 

Q24

 

0

 

4.5

5

 

 

Q25

 

4.5

 

0.7

4.5

 

 

Q26

 

0

 

0.7

0

 

 

Q30

 

4.0

 

0

0

 

 

 

Tx

 

B

 

C

E

0

2.0

0

4.0

 

1.0

1.5

4.5

 

0.7

0

0

 

0

0

4.5

 

4.5

4.5

0

 

0

3.3

3.0

 

15

15

3.0

 

0

0

4.0

 

0.7

4.0

0

 

4.0

4.0

3.0

 

0

0

0

 

4

4

4.5

 

0

4.5

4.0

 

0.7

4.0

0

 

4

4

0

 

0.4

0

4.0

 

0.7

4.5

0

 

4.5

5

4.5

 

0.7

4.5

3.0

 

0

4.0

4.0

 

0

0

Table 6-3 - Main Circuit Transistor Voltages

Issue 1.0

TROUBLESHOOTING

03/01

Page 6-3

Page 41
Image 41
Maxon Telecom SP200, SP210 service manual Voltage Charts, Transistors Main Circuit, Main Circuit Transistor Voltages