Maxon SP200/210 Radio

Environmental

Operating Temperature Range

Storage Temperature Range

Charging Temperature Range

Humidity

Protection against ingress of dust and water

Vibration

Robustness

ESD

EMC

Physical Dimensions

Synthesiser

Reference Crystal

Frequency:

Holder:

Accuracy:

Ageing Rate:

Synthesiser Lock Time: Switching Times

Tx to Rx, same frequency Rx to Tx, same frequency Rx to Rx

(over switching bandwidth) Rx to Tx / Tx to Rx

(over switching bandwidth)

Receiver Sensitivity

Squelch Sensitivity

Adjacent Channel Selectivity

Sub Audio Tones – CTCSS / DCS

SP200/210

-15 to +35°C (nominal) -20 to +55°C (extreme), -40 to +80°C (storage)

0 to +30°C

EIA/TIA 603 (95%)

IEC 529 IP54

BS2011 : Part 2.1Fc IEC 68-2-6

Part 2.1Fd IEC 68-2-34

Mil Std 810 C Procedures I, II & V

20kV (C-MIC >= 15kV)

EMC Directive 89/336/EEC May 89

112 x 61 x 40mm

(Excluding antenna and with QPA1350 pack)

12.8MHz HC-18

±3ppm over –30 to +60° C

<2ppm / Year in the first year

<1ppm / Year in subsequent years

<10mS

<20mS

<20mS

<20mS

<20mS

<-118dBm (VHF), <-117dBm (UHF)

7 – 12dB SINAD

Better than 70dB

Decode Sensitivity Method (decrease signal level @ 10% peak deviation)

All tones

<=9dB SINAD

CTCSS Tone Range

67

– 250Hz @ 0.3% accuracy

 

50

– 260Hz @ 0.3% accuracy (non-standard tones)

DCS Tone Standard

 

Standard & Inverted

Programmer

 

SMP 6100

SPECIFICATIONS

DRAFT

Issue 1.0

Page 2-2

 