Maxon SP200/210 Radio SP200/210
SPECIFICATIONS DRAFT Issue 1.0
Page 2-2 03/01
Environmental
Operating Temperature Range -15 to +35°C (nom inal)
-20 to +55°C (extreme),
Storage Temperature Range -40 to +80°C (storage)
Charging Temperature Range 0 to +30°C
Humidity EIA/TIA 603 (95%)
Protection against ingress of IEC 529 IP54
dust and water
Vibration BS2011 : Part 2.1Fc IEC 68-2-6
Part 2.1Fd IEC 68-2-34
Robustness Mil Std 810 C Procedures I, II & V
ESD 20kV (C-MIC >= 15kV)
EMC EMC Directive 89/336/EEC May 89
Physical Dimensions 112 x 61 x 40mm
(Excluding antenna and with QPA1350 pack)
Synthesiser
Reference Crystal
Frequency: 12.8MHz
Holder: HC-18
Accuracy: ± 3ppm over –30 to +60°C
Ageing Rate: < 2ppm / Year in the first year
< 1ppm / Year in subsequent years
Synthesiser Lock Time: < 10mS
Switching Times
Tx to Rx, same frequency < 20mS
Rx to Tx, same frequency < 20mS
Rx to Rx < 20mS
(over switching bandwidth)
Rx to Tx / Tx to Rx < 20mS
(over switching bandwidth)
Receiver Sensitivity <-118dBm (VHF), <-117dBm (UHF)
Squelch Sensitivity 7 – 12dB SINAD
Adjacent Channel Selectivity Better than 70dB
Sub Audio Tones – CTCSS / DCS
Decode Sensitivity Method (decrease signal level @ 10% peak devia tion)
All tones <=9dB SINAD
CTCSS Tone Range 67 – 250Hz @ 0.3% accuracy
50 – 260Hz @ 0.3% accuracy (non-standard tones)
DCS Tone Standard Standard & Inver ted
Programmer SMP 6100